INSTALLATION AND OPERATION MANUAL
Thank you for purchasing this product from a fine line of heating equipment.
We wish you many years of safe heating pleasure.
Visit our web page at
frequently asked questions, parts & accessory orders and more.
NOTE: IF YOU HAVE A PROBLEM WITH THIS UNIT DO NOT RETURN IT TO
THE DEALER. CONTACT CUSTOMER SERVICE @ 1-800-245-6489.
READ THESE INSTRUCTIONS CAREFULLY BEFORE INSTALLATION
CAUTION: This unit must be installed in accordance with these instructions and must
comply with local building and fire codes. Failure to do so could result in a chimney or
house fire, property damage, bodily injury or even death.. Keep children, furniture,
fixtures and all combustibles away from any heating appliance.
England's Stove Works highly recommends the use of smoke detectors and Carbon
Monoxide detectors with any hearth product, including this unit. Follow all manufacturer's
instructions when using smoke or Carbon Monoxide detectors.
DO NOT INSTALL THIS UNIT IN A MOBILE HOME OR DOUBLE WIDE!
DO NOT INSTALL THIS UNIT IN A PRE-MANUFACTURED FIREPLACE!
FOR MASONRY FIREPLACE INSTALLATION ONLY.
This product contains a catalytic combustor, which needs periodic inspection and
replacement for proper operation. It is against the law to operate this wood heater in a
manner inconsistent with the instructions in the manual or if the catalytic element is
deactivated or removed.
Our catalytic stoves are designed to burn seasoned, dry wood.
24-JC, 50-SHW20 and 50-TRW20
TYPE OF FUEL
EMISSION RATE
OVERALL EFFICIENCY
HEAT OUTPUT TEST RANGE
EPA CERTIFICATE NUMBER
THIS UNIT IS CERTIFIED TO EPA PHASE II STANDARDS
Rev. 1/06
www.englandsstoveworks.com
CAUTIONS AND WARNINGS:
COMPLIANCE STATUS
for helpful information,
WOOD
2.1 GRAMS PER HOUR
83.04%
7,200 TO 28,600 BTU/HR
267

Advertisement

Table of Contents
loading

Summary of Contents for England's Stove Works 24-JC

  • Page 1 Keep children, furniture, fixtures and all combustibles away from any heating appliance. England’s Stove Works highly recommends the use of smoke detectors and Carbon Monoxide detectors with any hearth product, including this unit. Follow all manufacturer’s instructions when using smoke or Carbon Monoxide detectors.
  • Page 2: Safety Notice

    If the area of the flue is larger than the area of the opening on the stove, it should never be more than three (3) times larger.
  • Page 3 Place the gasket on the outer perimeter of the rear of the cover plate before mounting the plate over the stove. The four welded metal clips on the rear of the cover plate will secure the plate to the unit by hooking over the flange on the stove; the clips can be sprung out with a flat head screwdriver as the plate is dropped down over the stove.
  • Page 4: Section Iv: Accessory Items

    SECTION IV: ACCESSORY ITEMS AC-104 (SH-104) Brass Trim The AC-104 trim kit covers the two front edges of the stove and the three edges of the cover plate. The stove lip trim simply snaps over the edges of the stove. There are two angle clips that hold the three pieces of cover plate trim together –...
  • Page 5 The unit has a slide damper located above the door that allows combustion air to enter the stove, and controls the amount of air and the total heat output of the unit. In the right position the damper is completely closed, and sliding it to the left allows air to enter the firebox.
  • Page 6: Section Vi: Care And Maintenance

    4. Allow the stove to burn for about 15 to 20 minutes with the door cracked one-half inch (½”). 5. You can close the door completely, but leave the draft controls open. Allow the stove to burn 10 to 15 minutes in this mode.
  • Page 7: Section Vii: Chimney Maintenance

    The blower system for this unit is placed under the ash lip and moves air under, around and finally exits over the top front of the stove. This blower should be removed and cleaned at least once a year; you can use a vacuum cleaner to remove any loose dust build-up, but do not disassemble the blower.
  • Page 8: Section Viii: Things That Cause The Unit To Smoke

    SECTION VIII: THINGS THAT CAUSE THE UNIT TO SMOKE It is very important that installations are made airtight – this is best accomplished by making any clean-out doors airtight and being sure there is no gap between the backplate and the brick fireplace face. All combustion air entering the system should be drawn through the slide draft opening which is located above the door.
  • Page 9 Have this information on hand if you phone the factory or your dealer regarding this product. Retain for your files: Model Number __________________________ Date of Purchase ________________________ Date of Manufacture _________________ Serial #_____________________ LIMITED 5 YEAR WARRANTY FROM THE DATE OF PURCHASE TO THE ORIGINAL OWNER The manufacturer extends the following warranties: Five Year Period: 1.
  • Page 11: Dealer Information

    WARRANTY REGISTRATION for England’s Stove Works Purchased by (Name) ______________________________________________ Address _________________________________________________________ City ________________________ State __________ Zip _________________ Telephone _______________________________________________________ Email Address ___________________________________________________ Purchased From (Dealer) ___________________________________________ Address _________________________________________________________ City ________________________ State __________ Zip _________________ (Please be sure to refer to sticker on back of manual or box to complete this section)

This manual is also suitable for:

50-shw2050-trw20

Table of Contents