Input Power; Voltage Rating - Emerson Packaged Drives and Engineered Systems Brochure

Packaged drives and engineered systems
Table of Contents

Advertisement

www.emersonct.com
800-533-0031
AC RapidPak Order Code Configurator
Order String
R
Product
R = RapidPak
Enclosure Style
S = Slimline
2
C = Cube
1
Drive Model
SKN = SK Normal Duty
SKH = SK Heavy Duty
CGN = GP20 Normal Duty
CGH = GP20 Heavy Duty
SPN = SP Normal Duty
SPH = SP Heavy Duty

Voltage Rating

8 = 208 V / 3 / 60
2 = 230 V / 3 / 60
3 = 380 V / 3 / 60
4 = 460 V / 3 / 60
Horsepower
see Order Code tables
1 Cube Enclosure Style does not allow for additional options (insufficient space)
2 Smallest Slimline Enclosure Style allows all the options unless bypass is selected,
then there is a limit of either an input or output reactor.
3 Abbreviation Key: PB = Push button; SS = Selector Switch; HOA = Hand-Off-Auto
Order string: The base Order Code requires a minimum of 12 characters in sequence to create the order string.
Additional Order Code
AC Input Reactor
AC Output Reactor
Auto Three-Contactor Bypass
Blower Motor Starter
Manual Three-Contactor Bypass
Nema 3R Enclosure
For options not included in the Order Code configurator, please consult factory.
x
xxx
x
xxx
x
x
3% impedance input line reactor. Reduces harmonics to line. Slimline only
3% impedance output line reactor. Increases motor insulation life by reducing dV/dt. Slimline only
Used in applications where full speed operation is required if drive becomes inoperable. Automatically switches
upon drive fault. Requires Operator Station #5. Slimline only
Controls separately powered motor blower on TEBC and DPFV motors used for wide speed range applications.
Not available with Bypass Options. Slimline only
Used in applications where full speed operation is required if drive becomes inoperable. Manual (operator)
activated via Operator Station #5. Slimline only
Enclosure intended for outdoor use. Provides a degree of protection against falling rain, sleet, and external ice.
x
-
xxxxx
Additional Options (if required)
1 = AC Input Reactor
2 = AC Output Reactor
4 = Auto 3-Contactor Bypass
5 = Blower Motor Starter
A = Manual Three-Contactor Bypass
F = NEMA-3R Enclosure

Input Power

0 = Main Lugs with Input Fusing
1
= Thru-Door Disconnect C/B
2 =
Thru-Door Disconnect Switch
Keypad
N = Keypad on Drive
K = Keypad on Door
Door Mounted Operator Station
0 = Blank
1 = Stop PB, Start PB, Fault Light, Pot
2 = #1 + JOG PB, Fwd/Rev SS
3 = #2 + Power On Light
4 = HOA SS, Power On, VFD Run, Fault Light, Pot
5 = HOA SS plus Bypass