Circuit Switch Communications; Configuring Circuit-Switch - Sierra Wireless Raven 1x User Manual

For telus
Table of Contents

Advertisement

B: Circuit Switch Communications
Step by Step
Configuration
Step by Step
Configuration
Note: When the Raven is used
for circuit switch, the circuit
switch configuration will disable
all ALEOS features except for
serial port communication.
Rev 3.0B Feb.08
Circuit‐switch communication requires the Raven to be in 
PassThru mode, communicating directly with the internal 
hardware. 
PassThru mode disables the use of ALEOS in the modem. Any 
features available using ALEOS are not usable when the 
modem is in PassThru mode. In PassThru mode, the settings 
available are those of the internal hardware. The Raven C3211 
in PassThru mode can save settings internally like a conven‐
tional analog modem. The Raven C3210 or C3216 in PassThru 
mode can not.
The best machines for use in circuit‐switched mode are ones 
that can provide their own INIT or setup strings and/or issue 
AT commands. For customers who have unintelligent 
machines who still need to have the modem ʹreadyʹ to behave 
in a certain way (such as Auto‐Answering circuit‐switched 
data calls), there is a feature in the modem called the INIT 
STATE.
For CDMA/1x, circuit‐switched configuration requires a voice 
plan (account) with your carrier, not a 1xRTT data plan. 1xRTT 
features are not compatible with the circuit switch configu‐
ration. Voice plan speeds are generally lower than those of a 
data plan. It is generally not easy to switch from one plan to 
the other. 

Configuring Circuit-Switch

The Raven needs to be configured to enter into PassThru after 
start up.   You can use AceManager (preferred) or direct serial 
communication to configure the Raven to work in PassThru 
mode and for circuit‐switched communications. In the UDP 
group, select the MD command and choose 07‐PassThru. 