Picture monitor (PM) displays
z Operation displays (manual)
z
The operation displays appear at the bottom of the screen for 4 seconds
when any of the following operations have been performed with the
operation panel of the ROP .
z "MASTER GAIN" is changed
z "SHUTTER" is changed
z "LENS EXT" is changed
z "FILTER" is changed
z "SCENE FILE" is changed
z "REF LOAD" is changed
The display time can be changed from "MAINTENANCE" menu → "PM
OPERATION STATUS" → "STATUS DISP TIME" .
FILTER FIL1
Item
Display
range
MASTER GAIN
Setting
values on
camera
SHUTTER
Setting
values on
camera
LENS EXT
1 .0
2 .0
FILTER
4 characters The name of the ND filter is displayed
SCENE FILE
SCENE1
SCENE4
OFF
REF LOAD
FACTORY
USER1
USER2
USER3
(Continued)
Remarks
The master gain value is displayed
here .
(in 3 dB increments)
z For the setting values, refer to the
z
Operating Instructions for the camera .
The speed of the electronic shutter is
displayed here .
z For the setting values, refer to the
z
Operating Instructions for the camera .
The magnification of the lens extender
is displayed here .
z When the magnification of the
z
lens extender is set to 2×, "2 .0" is
displayed .
Otherwise, "1 .0" is displayed .
here .
This indicates the scene file name .
This indicates the reference file that was
loaded using the SCENE command .
z Operation displays (AUTO)
z
If the AWB function, ABB function, or AUTO SETUP function has
been activated when a menu is not displayed on the picture monitor,
information on the operation performed appears at the bottom of the
screen .
When the AUTO SETUP operations are displayed, they will remain
displayed until the operations are completed .
The display is cleared 4 seconds after the operations are completed .
If the operations cannot be completed, they will remain displayed until
the NG (error) items of the AUTO function are released .
The display time can be changed from "MAINTENANCE" menu → "PM
OPERATION STATUS" → "STATUS DISP TIME" .
A UTO SET UP: AC TIVE
GAM MA OPE RAT ION
Display description:
Appears on two lines at the bottom of the screen .
Item
Top line: status
Bottom line: Detailed information
ABB START
ABB: ACTIVE
(None)
AWB START
AWB: ACTIVE
(None)
AUTO OK
ABB: OK
(Common to
(None)
ABB, AWB, and
AUTO SETUP)
AUTO NG1*
1
ABB: NG
(Only for ABB
Detailed information of the NG (error) message is
and AWB)
displayed here*
AUTO SETUP
AUTO SETUP: ACTIVE
START*
2
Detailed information is displayed here*
AUTO NG2*
AUTO SETUP: NG
3
(Only for AUTO
Detailed information of the NG (error) message is
SETUP)
displayed here*
AUTO BREAK
ABB: BREAK
(Common to
(None)
ABB, AWB and
AUTO SETUP)
AUTO READY
AUTO SETUP: READY
(Only for AUTO
(None)
SETUP)
AWB: OK
AUTO SETUP: OK
AWB: NG
1
.
.
2
.
3
AWB: BREAK
AUTO SETUP: BREAK
7