Real Time Installation Verification - Clarion UNGO MS8200 Installation Manual

Pro security system
Table of Contents

Advertisement

Real Time Installation Verification

This feature allows the installer to quickly and effectively check all aspects of the installation.
To enter Real Time System Verification:
1. Enter the vehicle.
2. Close the vehicle doors, hood, and trunk.
3. Turn on the ignition.
4. Within 4 seconds, press the Mode button then press and hold Button 1 for 5 seconds.
• The siren will emit one long chirp.
• The Starter Kill and the Armed outputs will activate.
5. You can now test the system.
I. Input Test
Test the starter kill by turning the ignition key to the start position.
• The car should not start.
Test the door input. (Open the door)
• The siren will chirp once.
With the door open:
Test the override switch.
• The status LED will flash while the override switch is held.
Test the Sensor Defeat input wire (Gray/black).
• The status LED will turn on solid while the Sensor Defeat input is grounded.
Test the Hood / Trunk input.
• The siren will chirp 4 times when the hood or trunk is opened.
Close the door.
With the door closed:
Test the Optional Sensor (White/violet) and Warn Away (Violet/yellow) inputs.
• When the system detects a signal on the Warn Away input, the siren will emit 2
short chirps.
• When the system detects a signal on the Optional Sensor input, the siren will will
emit 3 short chirps.
II. Output Test
To test the system's outputs, press the Transmitter Button corresponding to the function
that you want to test.
Button 1
Button 2
mode + 2
mode + mode + 1
mode + mode + 2
mode + mode + mode + 1 =
Page 24 - MS8200 / MS8300 Installation Manual
=
parking lights
=
dome light
=
door lock output
=
door unlock output
=
horn
siren