Seven Event Trigger History - Clarion UNGO MS8200 Installation Manual

Pro security system
Table of Contents

Advertisement

Seven Event Trigger History

This feature allows you to recall, from the system's memory, the events (zones) that have
triggered the system during the last seven times the system was armed. This is especially useful
in diagnosing sensors that are causing the system to trigger and need adjustment.
To enter Trigger History:
1. Turn on the ignition.
2. Open the door.
3. After 4 seconds, press Button 1 on the Remote Transmitter.
• The siren will chirp once.
• The LED will flash to indicate the zones that last triggered the system.
1 flash
2 flashes
3 flashes
4 flashes
5 flashes
The LED will continue to flash for 60 seconds or until the Transmitter Button is pressed
again.
4. To view the next previous triggering event, press Button 1 again.
• The siren will chirp once and the LED will flash to show the next previous event.
• If there are no other events in the system's memory, the siren will chirp two times.
5. To clear the Trigger History, press Button 2.
• The siren will chirp 5 times and erase all Trigger History data.
If the Trigger History is not cleared before the ignition is turned off, the Trigger
History data will be retained in the system's memory for further use.
6. To exit, turn the ignition off.
Page 26 - MS8200 / MS8300 Installation Manual
= door
= Logic Sensor II (shock)
= Space Shield III or optional sensor
= hood/trunk
= Logic Sensor II (motion)

Hide quick links: