5.3 Cutting pressure / Position of the stationary knife

3
2
1
Caution: Danger of injury!
Switch off main switch.
Check and adjust stationary knife only when the button
sewing automat is switched off.
Standard checking
The thread trimmer lever 2 should have a distance of 18.5 mm to the
front edge of the throat plate 3.
There must be a distance of 0.5 mm between the needle hole 4 and
counter-knife 5.
The knife 1 should be aligned in such a way that both threads are
safely cut in the middle of the cutting area and with the lowest possible
pressure.
A low cutting pressure ensures a low wear and tear of knives.
Measure the distance between the thread trimmer lever 2 and the
front of the throat plate 3.
Measure the distance between the needle hole 4 and the
counter-knife 5.
Turn handwheel until the hook knife can be swivelled in manually.
Swivel out hook knife.
Lay two threads to be cut in the hook knife.
Turn the handwheel until the hook knife has swivelled back.
Check whether the sewing threads are neatly cut.