Download Print this page

Casablanca Verrazano Instructions Manual

Hide thumbs Also See for Verrazano:

Advertisement

Quick Links

INTRODUCTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
MOUNTING RECOMMENDATIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
PREPARATION INSTRUCTIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
FAN INSTALLATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
CONTROL FEATURES:
W-1811 OPERATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
TROUBLESHOOTING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Safety and the proper operation of your Casablanca fan both require a thorough knowledge of the product
and proper installation; therefore, before attempting to install and operate your Casablanca fan, read this
owner's manual completely and carefully. Retain this manual for future reference.
CAUTION: To avoid possible electrical shock, make certain that electricity is turned off at
the circuit breaker or fuse box before attempting any installation procedure.
• All wiring must be in accordance with the National Electric Code ANSI/NFPA 70-1993 and the appropriate local electrical
codes. The National Electric Code requires proper grounding as a precaution against electrical shock. A qualifi ed electri-
cian should be consulted if you are unsure.
• This fan is designed to be installed on an existing electrical outlet box. The outlet box must be UL Listed for ceiling
fan installations. If it is not, a new box must be installed. Casablanca extension poles are available for sloped or high
ceiling installations.
• This ceiling fan requires a grounded electrical supply of 120 VAC, 60 Hz and a minimum 15-amp circuit. The maximum
current requirement for the fan with light fi xture is 3.8 amps. The fan uses about 1 amp or 100 watts. Maximum light
current is 0.83 amps (100 watts) of lighting.
• Where wire nuts are employed, be sure all bare wires are within the connectors. When installing the canopy hatch, make
sure all wires are within the canopy and that no wires are being pinched.
• The fan must be supplied with 3 independent 120V AC supply wires to provide power for the fan, the light, and neutral.
use only genuine Casablanca blades, light fi xtures, and accessories.
• The blades in each pack are matched for
equal weight to assure smooth fan operation.
If more than one fan is being installed, be
careful not to mix blades from different
cartons.
• Inspect the contents of your carton for
possible shipping or handling damage. If
parts are missing or damaged, call 1-888-
227-2178.
• It is always a good idea to have an assistant
to help with the installation.
• When cleaning, painting, or working near
your fan, be very careful of the fan and
blades. Always turn the power OFF to the
ceiling fan before servicing it, working on
it, or replacing lightbulbs.
• Never insert anything into the path of the
fan blades while the fan is in operation.
• Never install a fan over a pool or spa.
• Never operate a fan that has been damaged in
any way. Contact Casablanca Fan Company by
calling 1-888-227-2178, or contact your local
Authorized Casablanca Dealer for assistance
in obtaining service.
CONTENTS
READ AND SAVE THESE INSTRUCTIONS

SAFETY FIRST

BEFORE YOU START
For best performance and for your warranty to be valid,
SAFE USE
FUSE BOX
(REMOVE FUSE FOR THE
CIRCUIT YOU WILL BE
WORKING ON)
CIRCUIT BREAKER
(TRIP BREAKER FOR THE
CIRCUIT YOU WILL BE
WORKING ON)
P/N 6543010 REV. F
18"
DIMENTIONS INDICATED ARE THE
MINIMUM ALLOWABLE FOR PROPER
INSTALLATION
P/D AT0208
FROM BOTTOM
EDGE OF BLADE
TO FLOOR
84"
1

Advertisement

loading

Summary of Contents for Casablanca Verrazano

  • Page 1: Table Of Contents

    • Never install a fan over a pool or spa. • Never operate a fan that has been damaged in any way. Contact Casablanca Fan Company by DIMENTIONS INDICATED ARE THE MINIMUM ALLOWABLE FOR PROPER...
  • Page 2: Mounting Recommendations

    MOUNTING RECOMMENDATIONS Before mounting your Casablanca fan, read the following helpful recommendations. The location of the fan, air circulation, and fan size are all important factors to consider before installation. Location Ceiling fans have practical uses in almost every room in your home. We suggest you follow these mount- ing recommendations as you decide where to install your Casablanca fan.
  • Page 3: Preparation Instructions

    ™ ERRAZANO PREPARATION INSTRUCTIONS Unpacking: Before assembling and installing your ceiling fan, remove all parts from the shipping cartons and check them against the parts listed here. Before discarding packaging material, be certain that all parts have been removed. GETTING STARTED Carton Contents Be sure to use only genuine Casablanca blades.
  • Page 4: Fan Installation

    CEILING HARDWARE ADDITIONAL HARDWARE ” x 8-32 ROUNDED HEAD SCREW (2) CROSSBAR MOUNT- WIRE NUT (4) 1” x 8-32 ROUNDED ING BRACKET FLAT WASHER (2) HEAD SCREW (2) SUPPORT INSTALLATION PARTS LARGE LAG SCREW FLAT WASHER ¼” #7 X 5” (1) ¼”...
  • Page 5 ™ ERRAZANO LAG SCREW INSTALLATION Step 3. With the large washer attached, pass the lag screw through the center hole of the crosbar mounting bracket and screw into guide hole. Tighten until outlet box is fi rmly mounted to beam. This box must be secured fi rmly to the ceiling.
  • Page 6 HANGING THE FAN Step 5. To hang the fan body in the canopy, hold the fan CANOPY body fi rmly and insert the nylon ball into the canopy open- ing. Rotate fan body until slot on nylon ball fi ts into pin opposite canopy opening.
  • Page 7 ™ ERRAZANO INSTALLATION OF WALL CONTROL Step 6b. The W-18 / W-28 is designed to replace a standard 7. Install the W-18 / W-28 in the wall box with the two long wall switch and will fi t wall boxes (metal or plastic) with screws provided.
  • Page 8 BLADE HARDWARE BLADE TIP SCREW BLADE SCREW (2 PER BLADE) (3 PER BLADE) BLADE ROD BLADE TIP BLADE INSTALL BLADE RODS Step 10. Remove the shipping cover from each of the blade rod holders on the fan body. BLADE ROD Using the provided Allen wrench, unscrew Note: Do NOT HOLDER SCREW...
  • Page 9 ™ ERRAZANO LIGHT KIT PARTS LIGHT KIT SCREWS LIGHT KIT BULB PLATE LIGHT KIT BASE REMOVE SWITCH HOUSING SCREWS Step 13. Remove the three screws from the switch housing and set aside for use in Step 14. SWITCH HOUSING TABS SWITCH HOUSING SCREWS...
  • Page 10 INSTALL LIGHT KIT BASE Step 15. Attach the WHITE wire plug from the bulb plate to the WHITE wire plug of the fan. Then at- tach the BLACK wire plug from the bulb plate to the BLACK wire plug of the fan. The plugs have alignment tabs, assure these are aligned —do not force the connection.
  • Page 11: W-1811 Operation

    W-1811 CEILING FAN/LIGHT CONTROL W-1811 OPERATION 1. Raise the Fan slider to increase fan speed, lower it to decrease. 2. For the fan, four positions are available: OFF, LOW, MEDIUM, and HIGH. The bottom position is OFF. 3. The Light slider is a dimmer, the bottom is OFF; raise to increase intensity of the light.
  • Page 12: Troubleshooting

    TROUBLESHOOTING Before requesting service: Please consult this troubleshooting guide before contacting your dealer for assistance. FAN WILL NOT START Check main circuit fuses, circuit breakers, or wall switch position. Check all wire connections, making sure the power is turned off during this inspection. Check that reverse switch is not set in center of throw.
  • Page 13 ™ ERRAZANO AUTHORIZED SERVICE CENTERS STATE/CITY SERVICE CENTER NAME PHONE TYPE TYPES OF SERVICE OFFERED: FFS = FULL FAN SERVICE IHO = IN-HOME ONLY ISO = IN-SHOP ONLY COLORADO ISW = IN-SHOP ONLY/ONLY WHAT THEY SELL OWS = ONLY WHAT THEY SELL BOULDER 80306 ENERGETICTECH...
  • Page 14 AUTHORIZED SERVICE CENTERS STATE/CITY SERVICE CENTER NAME PHONE TYPE STATE/CITY SERVICE CENTER NAME PHONE TYPE IOWA NEBRASKA CARROLL 51401 J & L ELECTRIC INC. 712-792-2444 GRAND ISLAND 68803 QUALITY SEW & VAC 308-382-7310 CEDAR RAPIDS 52404 ACME ELECTRIC COMPANY 319-365-8677 LINCOLN 68510 LINCOLN LIGHTING CENTER...
  • Page 15 ™ ERRAZANO AUTHORIZED SERVICE CENTERS STATE/CITY SERVICE CENTER NAME PHONE TYPE STATE/CITY SERVICE CENTER NAME PHONE TYPE OHIO CARROLLTON 75006 ADFANTAGE CEILING FANS 972-446-9393 CANTON 44706 APPLIANCE PARTS CO. 330-453-8077 CORPUS CHRISTI 78404 BRAND APPLIANCE & MICROWAVE 361-854-1851 CLEVELAND 44109 WESTSIDE LIGHTING CTR.