Citizen PD24 Command Reference Manual page 51

Handy printer
Hide thumbs Also See for PD24:
Table of Contents

Advertisement

IrCZ infrared communication speed: n=20
● Sets the communication speed of the IrCZ infrared interface specification.
m = 0: 9600 bps
1: 19200 bps
2: 38400 bps
IrCZ infrared interface stop bit length: n=21
● Sets the stop bit length of the IrCZ infrared interface specification.
m=0: 1 stop bit
1: 2 stop bit
Setting the Link off: n=23
● Sets the link OFF control. "Link OFF control" disables the auto power-off control of the printer while the printer
is detected by device detection operation of the host during IrDA communication.
m=0: disabled
1: enabled
Setting the Bluetooth communication mode: n=25
● Sets the Bluetooth communication mode. In NORMAL, communication with any Bluetooth equipment is
available. In BOND, data are authenticated with a pass key before communication is connected. These are
available only with Bluetooth-equipped models.
m=0: NORMAL
1: BOND
Deleting the Bluetooth BOND history: n=26
● When Bluetooth communication mode is switched to BOND for authentication, the history record of the
authentication equipment called 'link key' is saved in the printer. Based on this record, authentication can be
skipped from the next time for already authenticated equipment. By enabling BOND history record deletion at
this time, all history records will be deleted at the next power-ON of the printer. After records are deleted, the
printer is automatically turned OFF and this setting as well automatically becomes ineffective. These are
available only with Bluetooth-equipped models.
m=0: invalid
1:valid
Setting the QR code division mode: n=27
● Sets the division barcode system of QR code. In division mode 1, the user divides data and prints out division
barcodes. In division mode 2, the printer divides a given data based on division specification information and
prints out division barcodes.
m=0: division mode 1
1: division mode 2
Selecting the type of interface: n=28
● Selects the type of interface.
m=0: Cable interface
1: IrDA interface