Table 8 — Fan Performance — 581A155300 (High Heat Units with Optional Indoor Fan Motor)
CFM
0.2
Rpm
Watts
Bhp
3750
753
942
1.08
4000
764
1035
1.19
4250
798
1177
1.35
4500
832
1331
1.53
4750
868
1498
1.72
5000
903
1677
1.93
5250
939
1871
2.15
976
2077
2.39
5500
5750
1012
2298
2.64
1049
2533
2.91
6000
CFM
1.2
Rpm
Watts
Bhp
3750
1227
1970
2.27
4000
1241
2116
2.43
1258
2274
2.62
4250
4500
1275
2445
2.81
1295
2629
3.02
4750
1315
2826
3.25
5000
1337
3037
3.49
5250
1360
3262
3.75
5500
5750
1384
3500
4.03
1410
3753
4.32
6000
LEGEND
Bhp
— Brake Horsepower
FIOP — Factory-Installed Option
Watts — Input Watts to Motor
*Standard low-medium static drive range is 834 to 1064 rpm. Alternate
high-static drive range is 1161 to 1426. Other rpms require a field-
supplied drive.
NOTES:
1. Maximum continuous bhp for the optional motor is 4.38. The maxi-
mum continuous watts is 3775. Do not adjust motor rpm such that
motor maximum bhp and/or watts is exceeded at the maximum
operating cfm.
AVAILABLE EXTERNAL STATIC PRESSURE (in. wg)
0.4
Rpm
Watts
Bhp
Rpm
844
1101
1.27
949
872
1236
1.42
972
901
1382
1.59
997
931
1540
1.77
1024
962
1711
1.97
1051
994
1896
2.18
1079
1026
2093
2.41
1109
1059
2304
2.65
1139
1093
2529
2.91
1170
1127
2768
3.18
1201
AVAILABLE EXTERNAL STATIC PRESSURE (in. wg)
1.4
Rpm
Watts
Bhp
Rpm
1310
2206
2.54
1390
1323
2353
2.71
1400
1337
2513
2.89
1413
1352
2687
3.09
1426
1369
2873
3.30
1442
1388
3073
3.53
1458
1408
3286
3.78
1477
1429
3513
4.04
1496
1452
3755
4.32
—20—
0.6
0.8
Watts
Bhp
Rpm
Watts
1306
1.50
1047
1520
1444
1.66
1067
1661
1594
1.83
1089
1814
1757
2.02
1112
1980
1932
2.22
1136
2158
2120
2.44
1161
2350
2321
2.67
1188
2554
2536
2.92
1215
2773
2765
3.18
1244
3005
3008
3.46
1273
3252
1.6
1.8
Watts
Bhp
Rpm
Watts
2448
2.82
1467
2696
2597
2.99
1475
2847
2759
3.17
1486
3010
2934
3.37
1498
3187
3122
3.59
1511
3377
3324
3.82
1527
3581
3540
4.07
3769
4.34
2. Static pressure losses (i.e., economizer) must be added to external
static pressure before entering Fan Performance table.
3. Interpolation is permissible. Do not extrapolate.
4. Fan performance is based on wet coils, clean filters, and
casing losses. See Table 13 for accessory/FIOP static pressure
information.
5. Extensive motor and drive testing on these units ensures that the full
bhp and watts range of the motor can be utilized with confidence.
Using your fan motors up to the watts or bhp rating shown will not
result in nuisance tripping or premature motor failure. Unit warranty
will not be affected.
6. Use of a field-supplied motor may affect wiring size. Contact your
Bryant representative for details.
1.0
Bhp
Rpm
Watts
Bhp
1.75
1139
1741
2.00
1.91
1156
1885
2.17
2.09
1175
2041
2.35
2.28
1195
2209
2.54
2.48
1217
2390
2.75
2.70
1240
2585
2.97
2.94
1264
2793
3.21
3.19
1289
3015
3.47
3.46
1315
3250
3.74
3.74
1342
3500
4.03
2.0
Bhp
Rpm
Watts
Bhp
3.10
1541
2951
3.39
3.27
1548
3102
3.57
3.46
3.67
3.88
4.12