CFM
0.2
Rpm
Watts
6,000
824
2607
6,500
881
3030
7,000
939
3488
7,500
998
3982
8,000
1056
4512
8,500
1116
5077
1175
5678
9,000
1235
6315
9,500
10,000
1295
6988
CFM
1.2
Rpm
Watts
6,000
1141
3829
6,500
1181
4247
7,000
1223
4702
1267
5194
7,500
8,000
1313
5721
1360
6285
8,500
9,000
1408
6885
1458
7521
9,500
10,000
1508
8193
CFM
2.2
Rpm
Watts
6,000
1399
5118
6,500
1429
5527
1462
5974
7,000
7,500
1498
6459
1535
6981
8,000
8,500
9,000
9,500
10,000
LEGEND
Bhp
— Brake Horsepower
FIOP — Factory-Installed Option
Watts — Input Watts to Motor
*Standard low-medium static drive range is 1002 to 1151 rpm. Alternate
high-static drive range is 1193 to 1369. Other rpms require a field-
supplied drive.
NOTES:
1. Maximum continuous bhp for the standard motor is 9.47 (for 208-v
units) and 10.33 (for 230 and 460-v units). The maximum continuous
watts is 7915 (for 208-v units) and 8640 (for 230 and 460-v units).
Do not adjust motor rpm such that motor maximum bhp and/or watts
is exceeded at the maximum operating cfm.
Table 6 — Fan Performance — 581A240270 (Low Heat Units)
AVAILABLE EXTERNAL STATIC PRESSURE (in. wg)
0.4
Bhp
Rpm
Watts
Bhp
3.09
894
2844
3.37
3.59
947
3266
3.88
4.14
1001
3725
4.42
4.72
1055
4218
5.00
5.35
1111
4748
5.63
6.02
1167
5314
6.30
6.74
1224
5915
7.02
7.49
1282
6552
7.77
8.29
1340
7225
8.57
AVAILABLE EXTERNAL STATIC PRESSURE (in. wg)
1.4
Bhp
Rpm
Watts
Bhp
4.54
1196
4082
4.84
5.04
1234
4499
5.34
5.58
1274
4953
5.88
6.16
1316
5443
6.46
6.79
1359
5970
7.08
7.46
1405
6533
7.75
8.17
1451
7132
8.46
8.92
1499
7768
9.22
9.72
1549
8440
10.01
AVAILABLE EXTERNAL STATIC PRESSURE (in. wg)
2.4
Bhp
Rpm
Watts
Bhp
6.07
1446
5381
6.38
6.56
1475
5789
6.87
7.09
1507
6234
7.40
7.66
1540
6717
7.97
8.28
0.6
Rpm
Watts
Bhp
Rpm
961
3085
3.66
1023
1009
3507
4.16
1069
1060
3965
4.70
1116
1111
4458
5.29
1165
1164
4988
5.92
1215
1218
5553
6.59
1266
1272
6154
7.30
1319
1327
6791
8.06
1372
1383
7465
8.86
1426
1.6
Rpm
Watts
Bhp
Rpm
1249
4337
5.15
1301
1285
4753
5.64
1334
1323
5205
6.18
1371
1363
5694
6.76
1409
1405
6220
7.38
1449
1449
6783
8.05
1491
1494
7381
8.76
1535
1540
8016
9.51
2.6
Rpm
Watts
Bhp
Rpm
1492
5647
6.70
1537
1520
6052
7.18
1550
6495
7.71
2. Static pressure losses (i.e., economizer) must be added to external
static pressure before entering Fan Performance table.
3. Interpolation is permissible. Do not extrapolate.
4. Fan performance is based on wet coils, clean filters, and
casing losses. See Table 13 for accessory/FIOP static pressure
information.
5. Extensive motor and drive testing on these units ensures that the full
bhp and watts range of the motor can be utilized with confidence.
Using your fan motors up to the watts or bhp rating shown will not
result in nuisance tripping or premature motor failure. Unit warranty
will not be affected.
6. Use of a field-supplied motor may affect wiring size. Contact your
Bryant representative for details.
—18—
0.8
1.0
Watts
Bhp
Rpm
Watts
3330
3.95
1083
3578
3751
4.45
1126
3998
4208
4.99
1170
4454
4701
5.58
1217
4946
5230
6.20
1264
5474
5795
6.87
1314
6039
6395
7.59
1364
6639
7033
8.34
1415
7276
7706
9.14
1468
7949
1.8
2.0
Watts
Bhp
Rpm
Watts
4596
5.45
1351
4856
5009
5.94
1383
5267
5460
6.48
1417
5716
5947
7.06
1454
6202
6472
7.68
1493
6726
7034
8.34
1533
7286
7631
9.05
2.8
3.0
Watts
Bhp
Rpm
Watts
5914
7.02
Bhp
4.24
4.74
5.28
5.87
6.49
7.16
7.88
8.63
9.43
Bhp
5.76
6.25
6.78
7.36
7.98
8.64
Bhp

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents