Brother MFC5100C Service Manual page 194

Facsimile equipment
Hide thumbs Also See for MFC5100C:
Table of Contents

Advertisement

Selector
No.
1
Selection of redial interval
2
3
|
No. of redialings
6
Redialing for no response sent
7
from the called terminal
8
Not used.
Selectors 1 through 6:
The equipment redials by the number of times set by selectors 3 through 6 at intervals set by
selectors 1 and 2.
Selector 7:
Redialing for no response sent from the called terminal
This selector determines whether or not the equipment redials if no G3 command response comes
from the called station after dialing within the time length set by selectors 7 and 8 of WSW09.
WSW15
(REDIAL facility setting)
Function
Selection of redial interval and No. of redialings
18
Setting and Specifications
No. 1
2
0
0
:
5 minutes
0
1
:
1 minute
1
0
:
2 minutes
1
1
:
3 minutes
No. 3
4
5
6
0
0
0
0
0
0
0
1
0
0
1
0
0
0
1
1
|
1
1
1
1
0: Redialing
:
16 times
:
1 times
:
2 times
:
3 times
|
:
15 times
1: No redialing

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mfc590