Installing And Administering The Terminal Server - Avaya MultiVantage Installation Manual

Adjuncts and peripherals
Table of Contents

Advertisement

Terminal server installation
Installing and administering the
terminal server
Make sure you have all the equipment on site before the installation. You must
have the hardware listed in
Table 14. Required equipment
Comcode
Description
700015084
IOLAN+ 104 communications server
NA
RJ45-to-DB25 connector for IOLAN+
(supplied with 700015084)
NA
DB25-to-DB9 connector for PC COM port
NA
RS232 Null modem (if needed for PC or
printer connectivity)
405369042
Male/female adapter (if necessary)
846943306
6-inch RJ45 crossover cord, or
or 104154414
NA
10/100Base-T auto-sensing LAN hub or
router
102631413
259A adapter, or
NA
CAT5 cross connect hardware and
connecting blocks
NA
RJ45 UTP Category 5 modular cords
NA
451A in-line RJ45 adapters, as needed to
connect modular cords together
You also need a computer (laptop) with the HyperTerminal software program for
the initial administration of the IOLAN+ and to set up the ports.
The general process is to
Connect the IOLAN+ to the adjunct and the LAN
Administer the ports on the IOLAN+ using a PC or laptop at the local site
Test the connectivity back through the switch
Distance limits
The distance limit from the switch to the LAN hub is 328 feet (100 meters). The
distance limit from the LAN hub to the terminal server is 328 feet (100 meters). If
installed, the limit from the terminal server to the adjunct is 50 feet (15 meters).
122
Issue 4 October 2002
Table
14.
Qty
Supplier
1
Avaya
4
Avaya
1
Avaya
1 or more
Avaya
1 or more
Avaya
1
Avaya
1
Customer
1
Avaya
Customer
1–2
Customer
555-233-116