Pro Logic
At the local display/keypad:
1.
Press "Menu" until Configuration Menu is displayed.
2.
Hold both "<" and ">" for three seconds.
3.
Press ">" repeatedly until "Chemistry Config. Wizard" is displayed.
4.
Push "+" to start Wizard.
5.
Advance through the Wizard until pH Reduction Control is displayed. Use "+" or
"-" to set pH Reduction Control to "Forced On".
6.
Continue through the Wizard and exit.
7.
Verify that acid solution is visible at the flow indicator.
8.
After the system is fully primed, return to the Chemistry Config. Wizard and set
the pH Reduction Control setting to "Auto Sensing".
Every pool is different and requires different acid feed rates. In most applications, the
pool controller will compensate for varying pool sizes and chemistries. If your pool is
overshooting (too much acid dispense) or timing out (not enough acid dispense), you
can adjust the pump rate as needed by turning the numbered collar on the pump.
Refer to Stenner pump manual for additional instructions relating directly to the pump
operation and service.
If the tank is full but the pool's pH is not adjusting or if the pool control continues to
show a "pH timeout" indication:
•
Check flow indicator for proper flow.
•
Ensure that the acid dilution is correct.
•
Check for leaks (pump tube, suction tube, discharge tube, all fittings)
•
Check pool chemistry (especially Total Alkalinity)
•
Check that suction line strainer is fully immersed
•
Check timeout setting
•
Adjust pump output higher
If the pool's pH is overshooting the pH setting:
•
Ensure acid dilution is correct
•
Check pool chemistry (especially Total Alkalinity)
•
Adjust pump output lower
•
Pump not operating as expected
•
See Stenner pump manual
Spare Parts
GLX-SP-LP5TUBE – peristaltic (pumping) tube
GLX-SP-UVTUBE – UV-resistant suction/discharge tubing with nuts and ferrules
GLX-SP-STRAINER – weighted suction line strainer
GLX-SP-CHECKV – injection check valve
GLX-SP-FLO – flow indicator
GLX-SADDLE – injection fitting and clamp
GLX-SP-DB - replacement duck bill
GLX-SP-ROLLER - replacement roller assembly
GLX-SP-PUMP-120 -replacement pump - 120V
GLX-SP-PUMP-240 -replacement pump - 240V
Troubleshooting