Installation Instructions; Built-In Outdoor Power™ Burner Installation; Install Tank Tray For 20 Lb Lp Gas Fuel Tank - KitchenAid KBPU182VSS Installation Instructions And Use And Care Manual

Outdoor built-in power burner
Hide thumbs Also See for KBPU182VSS:
Table of Contents

Advertisement

Available languages

Available languages

The gas supply line shall be equipped with an approved shutoff
valve. This valve should be located in the same area as the
Power™ burner and should be in a location that allows ease of
opening and closing. Do not block access to the shutoff valve.
The valve is for turning on or shutting off gas to the Power™
burner.
A
A. Gas supply line
B. Shutoff valve "open" position
C. To Power™ burner
Natural Gas Conversion
Conversion must be made by a qualified gas technician. The
qualified Natural gas technician shall provide the Natural gas
supply to the selected Power™ burner location in accordance
with the National Fuel Gas Code ANSI Z223.1/NFPA 54 - latest
edition, and local codes. For conversion to Natural gas, the
Natural gas conversion kit supplied with the Power™ burner
must be used.
IMPORTANT: The gas installation must conform with local
codes, or in the absence of local codes, with the National Fuel
Gas Code, ANSI Z223.1/NFPA 54 - latest edition.
To convert to Natural gas, the Natural Gas Conversion Kit
supplied with the Power™ burner must be used.
Built-in Outdoor Power™ Burner Installation
WARNING
Excessive Weight Hazard
Use two or more people to move and install side
burner.
Failure to do so can result in back or other injury.
Unpack Power™ burner. Remove all packaging materials and
remove Power™ burner from carton.
Place Power™ burner into outdoor enclosure, but leave
enough room in back to connect to gas supply and electrical
single prong plug-in.
B
C

INSTALLATION INSTRUCTIONS

Follow instructions for converting to Natural gas in the "Gas
Conversions" section.
A. New CSA International approved
"outdoor" flexible gas supply line
B. Rear of Power™ burner
C. To Natural gas supply
The gas supply line shall be equipped with an approved shutoff
valve. This valve should be located in the same area as the
Power™ burner and should be in a location that allows ease of
opening and closing. Do not block access to the shutoff valve.
The valve is for turning on or shutting off gas to the Power™
burner.
A
A. Gas supply line
B. Shutoff valve "open" position
C. To Power™ burner

Install Tank Tray for 20 lb LP Gas Fuel Tank

1. Position the tank tray for 20 lb LP gas fuel tank in the island
cabinet.
centerline of
tank tray
20 "
(52.4 cm)
A.
B. 16
A
B
C
B
C
A
18 "
B
(46.7 cm)
8
" (20.6 cm)
" (41.1 cm)
2 "
(5.7 cm)
11

Advertisement

Table of Contents
loading

Table of Contents