KitchenAid KBZU122T Installation Instructions And Use & Care Manual
KitchenAid KBZU122T Installation Instructions And Use & Care Manual

KitchenAid KBZU122T Installation Instructions And Use & Care Manual

Outdoor built-in dual side burners
Table of Contents

Advertisement

Available languages

Available languages

Quick Links

OUTDOOR BUILT-IN DUAL SIDE BURNERS
For questions about features, operation/performance, parts, accessories or service, call: 1-800-422-1230
DEUX BRÛLEURS LATÉRAUX ENCASTRÉS
Instructions d'installation et Guide d'utilisation et d'entretien
Au Canada, pour assistance, installation ou service composez le 1-800-807-6777 ou visitez notre site web à...
Table of Contents/Table des matières............................................................................. 2
IMPORTANT:
Save for local electrical inspector's use.
Installer: Leave installation instructions with the homeowner.
Homeowner: Keep installation instructions for future reference.
IMPORTANT :
À conserver pour consultation par l'inspecteur local des installations électriques.
Installateur : Remettre les instructions d'installation au propriétaire.
Propriétaire : Conserver les instructions d'installation pour référence ultérieure.
Models/Modèles KBZU122T KBZU242T
W10110732
Installation Instructions and Use & Care Guide
or visit our website at www.kitchenaid.com
In Canada, call for assistance, installation and service, call: 1-800-807-6777
or visit our website at www.KitchenAid.ca
POUR USAGE EXTÉRIEUR
www.KitchenAid.ca

Advertisement

Table of Contents
loading

Summary of Contents for KitchenAid KBZU122T

  • Page 1 À conserver pour consultation par l'inspecteur local des installations électriques. Installateur : Remettre les instructions d'installation au propriétaire. Propriétaire : Conserver les instructions d'installation pour référence ultérieure. Models/Modèles KBZU122T KBZU242T W10110732 or visit our website at www.kitchenaid.com or visit our website at www.KitchenAid.ca www.KitchenAid.ca...
  • Page 2: Table Of Contents

    TABLE OF CONTENTS OUTDOOR BUILT-IN SIDE BURNER SAFETY ...3 INSTALLATION REQUIREMENTS ...5 Tools and Parts ...5 Location Requirements ...5 Product Dimensions...5 Cabinet Dimensions ...6 Electrical Requirements ...6 Gas Supply Requirements ...7 INSTALLATION INSTRUCTIONS ...8 Outdoor Side Burner Installation ...8 Check and Adjust the Burners...9 USING YOUR OUTDOOR SIDE BURNER ...10 Lighting the Side Burner ...10 OUTDOOR SIDE BURNER CARE ...11...
  • Page 3: Outdoor Built-In Side Burner Safety

    OUTDOOR BUILT-IN SIDE BURNER SAFETY Your safety and the safety of others are very important. We have provided many important safety messages in this manual and on your appliance. Always read and obey all safety messages. This is the safety alert symbol. This symbol alerts you to potential hazards that can kill or hurt you and others.
  • Page 4: Important Safety Instructions

    IMPORTANT: This side burner is manufactured for outdoor use only. For side burners that are to be used at elevations above 2000 ft (609.6 m) orifice conversion is required. See “Gas Supply Requirements” section. It is the responsibility of the installer to comply with the minimum installation clearances specified on the model/serial rating plate.
  • Page 5: Installation Requirements

    INSTALLATION REQUIREMENTS Tools and Parts Gather the required tools and parts before starting installation. Read and follow the instructions provided with any tools listed here. Tools Needed ■ Tape measure ■ Small, flat-blade screwdriver ■ Flat-blade screwdriver ■ #2 and #3 Phillips screwdriver ■...
  • Page 6: Cabinet Dimensions

    Built-In Outdoor Side Burner Enclosure The enclosure for the built-in outdoor side burner is to be a minimum of 11" (28.0 cm) high x 23" (58.4 cm) deep x 14" (35.6 cm) wide for front to back model and 11" (28.0 cm) high x 17"...
  • Page 7: Gas Supply Requirements

    Recommended Ground Method The outdoor side burner, when installed, must be electrically grounded in accordance with local codes or, in the absence of local codes, with the National Electrical Code ANSI/NFPA 70, or Canadian Electrical Code, CSA C22.1. Copies of the standards listed above may be obtained from: CSA International 8501 East Pleasant Valley Rd.
  • Page 8: Installation Instructions

    The supply line shall be equipped with an approved shutoff valve. This valve should be located in the same area as the burner and should be in a location that allows ease of opening and closing. Do not block access to the shutoff valve. The valve is for turning on or shutting off gas to the appliance.
  • Page 9: Check And Adjust The Burners

    4. Open the manual shutoff valve in the gas supply line. The valve is open when the handle is parallel to the gas pipe. A. Closed valve B. Open valve 5. Test all connections by brushing on an approved noncorrosive leak-detection solution. Bubbles will show a leak.
  • Page 10: Using Your Outdoor Side Burner

    Slowly open the tank valve. NOTE: If flow limiting device activates, your grill may not light. If your grill does light, the flames will be low and will not heat properly. Turn tank valve and all control knobs off and wait 30 seconds.
  • Page 11: Outdoor Side Burner Care

    Rub in direction of grain to avoid scratching or damaging the surface. ■ ® KitchenAid Stainless Steel Cleaner and Polish Part Number 4396920 (not included) or KitchenAid Part Number 8212510 (not included): See “Assistance or Service” section to order. ■ Liquid detergent or all-purpose cleaner: ■...
  • Page 12: Troubleshooting

    To locate the KitchenAid designated service company in your area, you can also look in your telephone directory Yellow Pages. For further assistance If you need further assistance, you can write to KitchenAid with any questions or concerns at: KitchenAid Brand Home Appliances Customer eXperience Center...
  • Page 13: Warranty

    For the life of the product, when this grill is operated and maintained according to instructions attached to or furnished with the product, KitchenAid will pay for replacement of the stainless steel body housing due to defective materials or workmanship. For the life of the product, when this grill is operated and maintained according to instructions attached to or furnished with the product, KitchenAid will pay for replacement parts for the stainless steel grill burners.
  • Page 14: Sécurité Du Brûleur Latéral Encastré D'extérieur

    SÉCURITÉ DU BRÛLEUR LATÉRAL Votre sécurité et celle des autres est très importante. Nous donnons de nombreux messages de sécurité importants dans ce manuel et sur votre appareil ménager. Assurez-vous de toujours lire tous les messages de sécurité et de vous y conformer. Voici le symbole d’alerte de sécurité.
  • Page 15 IMPORTANT : Ce brûleurs latéral est conçu pour un usage à l'extérieur uniquement. Pour les brûleurs latéraux destinés à être utilisés à des altitudes supérieures à 2000 pi (609,6 m), il est nécessaire de convertir le gicleur. Voir la section “Spécifications de l'alimentation en gaz”.
  • Page 16: Exigences D'installation

    EXIGENCES D'INSTALLATION Outillage et pièces Rassembler les outils et pièces nécessaires avant de commencer l'installation. Lire et suivre les instructions fournies avec les outils indiqués ici. Outillage nécessaire ■ Mètre ruban ■ Petit tournevis à lame plate ■ Tournevis à lame plate ■...
  • Page 17: Dimensions Du Placard

    Enceinte du brûleur latéral encastré d'extérieur L’enceinte du brûleur latéral encastré d’extérieur doit comporter les dimensions minimales suivantes : 11" (28 cm) de hauteur x 23" (58,4 cm) de profondeur x 14" (35,6 cm) de largeur pour le modèle à configuration avant/arrière et 11" (28 cm) de hauteur x 17"...
  • Page 18: Spécifications De L'alimentation En Gaz

    Il est recommandé de raccorder le brûleur latéral sur un circuit distinct exclusif à cet appareil. La plaque signalétique est située à l'intérieur de la caisse du brûleurs latéral sur le côté droit. Voir l'illustration ci-dessous. A. Plaque signalétique des numéros de modèle et de série Méthode recommandée de mise à...
  • Page 19: Instructions D'installation

    Test de pressurisation à une pression relative inférieure à ½ lb/po² (3,5 kPa) ou 14" (35,5 cm) (colonne d'eau) : Le brûleur latéral devra être isolé de la canalisation de gaz par la fermeture du robinet d'arrêt manuel individuel durant tout test de pressurisation de la canalisation de gaz à...
  • Page 20: Contrôle Et Réglage Des Brûleurs

    2. On doit employer une combinaison de raccords pour raccorder le brûleur latéral à la canalisation de gaz existante. Si le code local le permet, pour le raccordement du brûleur latéral à la canalisation de gaz rigide, utiliser un conduit de raccordement flexible en acier inoxydable, homologué...
  • Page 21: Utilisation Du Brûleur Latéral D'extérieur

    Réglage pour le débit thermique minimum Si le brûleur s'éteint lorsqu'il est réglé pour le débit thermique minimum (position LO), on doit effectuer un réglage particulier. 1. Allumer le brûleur et tourner le bouton de commande au réglage le plus faible; puis, retirer le bouton. 2.
  • Page 22: Entretien Du Brûleur Latéral D'extérieur

    ■ Nettoyant et poli pour acier inoxydable KitchenAid Pièce n° 4396920 (non incluse) ou chiffons pour acier inoxydable KitchenAid - Pièce n° 8212510 (non incluse) : Voir la section “Assistance ou service” pour commander. ■ Détergent liquide ou nettoyant tout-usage ■...
  • Page 23: Dépannage

    à ou fournies avec le produit, KitchenAid paiera pour les pièces spécifiées par l'usine et la main-d'œuvre pour corriger les vices de matériaux ou de fabrication. Le service doit être fourni par une compagnie de service désignée par KitchenAid.
  • Page 24 Pour la durée de vie du produit, lorsque ce gril est utilisé et entretenu conformément aux instructions jointes à ou fournies avec le produit, KitchenAid remplacera la structure en acier inoxydable en cas de vices de matériaux ou de fabrication. Pour la durée de vie du produit, lorsque ce gril est utilisé...

This manual is also suitable for:

Kbzu242t

Table of Contents