To Install the 20 lb LP Gas Fuel Tank:
1. Open cabinet doors.
2. Pull out the tank tray.
3. Place the 20 lb LP gas fuel tank bottom collar into the
mounting hole in the tank tray.
4. Tighten the locking screw against the bottom collar of the
20 lb LP gas fuel tank to secure.
A
A. Locking screw
B. Mounting hole
C. Bottom collar
5. Screw the gas pressure regulator/hose assembly to the 20 lb
LP gas fuel tank as shown. (To disconnect, turn off the gas
supply to the 20 lb LP gas fuel tank, then unscrew the gas
pressure regulator/hose assembly from the 20 lb LP gas fuel
tank as shown.)
connect
disconnect
A
A. 20 lb LP gas fuel tank
B. Gas pressure regulator/hose assembly
6. Turn on the gas supply. Wait a few minutes for gas to move
through the gas line.
7. Test all connections by brushing on an approved
noncorrosive leak-detection solution. Bubbles will show a
leak. Correct any leak found.
8. Slide tank tray back into the cabinet.
9. Go to "Plug in Power™ Burner" in this section.
Tank tray
B
C
B
Gas Connection to Natural Gas or Local LP Gas
WARNING
Explosion Hazard
Use a new CSA International approved "outdoor"
gas supply line.
Securely tighten all gas connections.
If connected to LP, have a qualified person make sure
gas pressure does not exceed 11" (28 cm) water
column.
Examples of a qualified person include:
licensed heating personnel,
authorized gas company personnel, and
authorized service personnel.
Failure to do so can result in death, explosion, or fire.
This installation must conform with local codes and ordinances.
In the absence of local codes, installations must conform with
either the National Fuel Gas Code ANSI Z223.1 - latest edition, or
CAN/CGA-B149.1 Natural Gas and Propane installation code.
Copies of the standards listed above may be obtained from:
CSA International
8501 East Pleasant Valley Rd.
Cleveland, Ohio 44131-5575
National Fire Protection Association
One Batterymarch Park
Quincy, Massachusetts 02269
1. Make gas connections.
A combination of pipe fittings must be used to connect the
Power™ burner to the existing gas line.
If local codes permit, use an outdoor flexible stainless
steel tubing gas connector, design-certified by CSA
International, to connect the Power™ burner to the rigid
gas supply line. A
" diameter line is recommended.
Using a wrench to tighten, connect the gas supply to the
Power™ burner. Use pipe-joint compound on all non-
flared male threads. Do not kink or damage the flexible
connector when moving the Power™ burner.
Pipe-joint compounds suitable for use with LP gas must
be used. Do not use TEFLON
A. New CSA International approved
"outdoor" flexible gas supply line
B. Rear of Power™ burner
C. To Natural gas or local LP gas supply
†®TEFLON is a registered trademark of E.I. Du Pont De Nemours and Company.
®†
tape.
A
B
C
13