AL-DTM
59. Reserved
LOCKOUT
60. Number of Attempts Before Lockout
• Number of attempts before lockout must be 1-9 attempts.
• The number of attempts is reduced by half every time the keypad is locked out without a
successful code entry (default is 6 attempts).
• The attempt count is reset each time a valid code is entered.
61. Set the Attempts Lockout Time
• Lockout Time must be 1-60 seconds. This functions defines how long the keypad is
locked out after a series of unsuccessful attempts (default is 15 seconds).
62-63. Reserved
REMOTE INPUT
Remote Input Disable/Enable
• Wire a Normally Open Contact to Terminals 3 & 4. Momentarily close to allow person to
pass through door.
• Enter the functions below to Disable/Enable the Remote Input.
NOTE: The Remote Input is enabled as part of the default program.
64. Disable Remote Input
65. Enable Remote Input
66. Reserved
22
Programming Functions (cont'd)
[ _ ]
; 6 0
;
(Number of Attempts)
[ _ _ ]
; 6 1
;
(Lockout Time)
; 6 4 :
; 6 5 :
:
4
:
4
2