PERMANENT PASSAGE MODE
Passage Mode Enable/Disable - Schedule will not Override
Function 48 allows passage through the door without the need for a User Code. Re-Lock using Function
49.
Programmed Schedules will not override the state of the lock using functions 48 and 49. If it is required
that programmed schedules override Passage Mode, Enable/Disable Passage Mode using Functions
45/46. Use Function 50 to "undo" Functions 48 and/or 49, and therefore return the lock to all pre-existing
scheduled functions. Note: Functions 48-50 can only be enabled using the keypad. Warning: Function
49 will inhibit all scheduled Passage Mode events.
48. Enable Permanent Passage Mode
(This Function enabled through keypad only)
49. Disable Permanent Passage Mode
(This Function enabled through keypad only)
50. Return Lock to Normal Passage
Mode Schedule
(This Function enabled through keypad only)
(Locks will lock or unlock depending on the current schedule). Use Function 50 to "undo"
Functions 48 and/or 49, and therefore return the lock to all pre-existing scheduled functions.
NOTE:
PASS TIME
Pass Time
The Pass Time is the length of time the lock stays unlocked after a valid User Code is en-
tered. When the Pass Time expires, the lock will re-lock automatically. Use the functions
below to change the Pass Time to 3-5, 10 or 15 seconds. The Pass Time is defaulted to
3-5 seconds.
51. Set Pass Time 3 to 5 Sec.
52. Set Pass Time to 10 Sec.
53. Set Pass Time to 15 Sec.
54. Reserved
20
Programming Functions (cont'd)
See Scheduled functions 72 and 73 for Scheduled Passage Mode.