Alarm Lock Trilogy DL2800 Programming Instructions Manual page 15

Trilogy series standalone access control system
Hide thumbs Also See for Trilogy DL2800:
Table of Contents

Advertisement

Programming Functions (cont'd)
USERS (Continued)
5. User Enable with Timeout
(Enter Timeout, XXX Hours)
(This Function enabled through keypad only)
With Function 5, User Numbers must be between 2-200, 299 or 300. Hours must be between 1-999.
Function 5 can temporarily override a disabled User (disabled using Function 3 above).
Since this is a temporary feature, Function 5 can only be enabled using the keypad.
Example: Brian, User Number 157, rarely works at the office, but when he does, enable him for his 8 hour work day
("008") by entering Program Mode and pressing: ; 5 ; 157 ; 008 :.
NOTE: Up to 4 Timeout Functions may be pending at any one time. An error beep will sound when attempting to
program more than 4 Timeout Functions.
User Lockout Mode
Prevents all User Codes (Except User 1 Master Code) from operating the lock. Note: Other program-
ming functions or schedules will NOT re-enable Users. Users must be re-enabled with Function 7.
Note: Does not change the User enable/disable status. Note: If the lock is currently in Passage Mode
("door unlocked") and Function 6 is programmed, the lock will remain in Passage Mode.
6. Enable Total User Lockout Mode
(This Function enabled through keypad only)
7. Disable Total User Lockout Mode
(This Function enabled through keypad only)
8. Change User Programming Level Ability
User Number must be between 2 and 200. The ability to program one or more Programming
Levels may be selected.
Example 1: Allow "Basic" User 67 to program levels 1, 2 and 4. Enter:
; 8
; 6 7
NOTE: User 67 does not have access to Programming Functions with a Program Level
Ability of 3.
xample 2: Prevent User 67 from programming any programming levels. Enter:
E
; 8
; 6 7
NOTE: Having a Program Level Ability of 4 does not allow access to functions requiring
a Program Level Ability of 3, 2 or 1. If multiple levels are required, program for each
level that is required.
9. Enable User 300
(Service Code)
Service Code is a "One-Time-Only" code. Once it is used, it is disabled until enabled again.
10. Erase All Users Except the Master Code
(This Function enabled through keypad only)
Erases all User Codes except the Master Code (User 1).
11. Reserved
; 5
; 6 :
; 7 :
; 8
; 1 2 4 :
:
; 9 :
(User 1)
;
[ _ _ _ _ ]
;
(User Number)
;
[ _ _ _ ]
;
(User Number)
3
2 2
; 1 0
; 0 0 0 :
M
[ _ _ _ _ ]
:
(XXX Hours)
2
M
[ _ _ _ _ ]
:
(Programming Levels)
15