RadioLink Ei411H User Instructions

RadioLink Ei411H User Instructions

For use with ei168rc radiolink bases (with rc series alarms), radiolink smoke and carbon monoxide (co) alarms

Advertisement

Quick Links

A16111-R4-EI411&412-UC-ENG
3/3/10
2:39 PM
Models:
Ei411H
Ei412
Remote Control
For use with Ei168RC RadioLINK Bases (with RC Series
Alarms), RadioLINK Smoke and Carbon Monoxide (CO) Alarms
RF Light Indicator
located here
Contains vital information on the product's operation and
installation. Read and retain carefully. If you are just
installing this product the manual MUST be given to
the householder.
The Ei411H is a RadioLINK Remote Control Switch for
use with Fire Alarm Systems only. A Fire Alarm may
contain a combination of Smoke, Heat & Multi-Sensor
Alarms.
The Ei412 is a RadioLINK Remote Control Switch for
use with mixed Fire & Carbon Monoxide Alarm
Systems.
WARNING:
The Ei411H is for use with the following
models of RadioLINK Base / Alarm:
Ei168RC
Base fitted with Ei161RC Smoke Alarm
Ei168RC
Base fitted with Ei164RC Heat Alarm
Ei168RC
Base fitted with Ei166RC Smoke Alarm
Ei405
RadioLINK Smoke Alarm
Ei405TY
RadioLINK Smoke Alarm
Ei605MRF
Module fitted with Ei605 Series Smoke Alarm
Ei605MTYRF
Module fitted with Ei605TY Series Smoke Alarm
The Ei412 works with all of the above plus
the Ei262 Carbon Monoxide Alarm
Ei262
CO Alarm with Integrated RadioLINK
Do not use any other models of RadioLINK
Base / Alarm
1
Page 1
on the Ei412 three red light indicators with flash in
1. INTRODUCTION
sequence.
For use with Ei168RC RadioLINK Bases (fitted with
4. It is essential that you House Code your Remote
RC Series Alarms) and RadioLINK Smoke and
Control Switch with your Smoke/Heat/CO Alarms and
Carbon Monoxide (CO)Alarms.
any RadioLINK accessories to prevent false alarms and
The Remote Control Switch allows you, without the
other interference with nearby systems (see below).
use of ladders or chairs, to:
• Test the Smoke/Heat/CO Alarms.
• Locate the Smoke/Heat/CO Alarm sensing fire/CO
by silencing all the other alarms (for 10 minutes). This
is of great benefit, particularly at night as the source of
the fire/CO can be quickly traced audibly. This is ideal
for larger systems as people nearest the fire/CO can
be quickly evacuated and/or control a fire if it is small.
• Memory Locate: The Locate button also identifies
which alarms have previously sensed fire/CO. This is
very useful when troubleshooting systems of multiple
smoke, heat and/or CO alarms (see section 4 - Alarm
Memory Function).
• Hush Nuisance Alarms: These can be silenced by
pressing and releasing the Hush switch.
• Fire & CO Indicators: In a Fire only System the Fire
indicator on the Ei411H will flash to indicate a fire has
To House Code your Remote Control Switch:
been detected.
a) Place all the RadioLINK Smoke/Heat/CO alarms
If there is a fire, immediately evacuate the premises
and accessories into House Code mode within 15
and telephone the fire brigade from outside. Do not
minutes, as described in their instruction leaflets.
silence the alarm unless you are sure there is no
b) Also, within the same 15 minutes, place the Remote
fire.
Control Switch into House Code mode by pressing and
In a mixed RadioLINK Fire & CO System the Fire or
holding the House Code button until the RF indicator
CO indicator on the Ei412 will flash to indicate that
red light turns on. Immediately release the button and
Fire (smoke/heat) or Carbon Monoxide has been
the RF indicator red light will now flash continuously
detected.
(for 15 minutes) to show it is in House Code mode.
If there is a fire, immediately evacuate the premises
c) The Remote Control Switch will now send a radio
and telephone the fire brigade from outside. Do not
message every 5 seconds to indicate it is in House
silence the alarm unless you are sure there is no
Code mode. All Smoke/Heat/CO Alarms and
fire.
accessories within range that are also in House Code
If CO has been detected, open doors & windows
mode themselves, will memorise the House Code of
while evacuating the premises. Telephone the
the Remote Control Switch.
appropriate authorities to report a Carbon Monoxide
d) Check that the number of amber light flashes (for
alarm has been activated.
RadioLINK Bases) or blue light flashes (for
RadioLINK Smoke Alarms) or RF indicator red light
2. INSTALLATION
flashes (for CO Alarm & Remote Control Switch)
1. Position the Remote Control Switch 1.2 metres
correspond with the number of units in the system
(approx) up on a wall in a suitable position on an exit
(e.g. smoke alarms plus the Remote Control Switch).
route. Avoid locating near metal objects.
For example, with 3 RadioLINK bases and one
Remote Control Switch you should see 4 amber light
2. Securely attach the mounting box of the unit to the
flashes from each base and 4 RF indicator red light
wall using the fixing screws supplied. Note: The
flashes on the Remote Control Switch.
Ei411H / 412 should not be recessed mounted - only
the surface mounting box supplied should be used.
e) The Remote Control Switch and Smoke/CO alarms
will exit the House Code mode by itself after
3. Carefully slide the battery switch into the 'ON'
approximately 15 minutes without further user
position (see Figure 1). On the Ei411H two red light
intervention.
indicators will flash in sequence to indicate power-up,
2
(However, this could result in problems with nearby
systems, if their units are being House Coded at the
same time. If this is the case exit House Code mode
by pressing and holding the House Code button until
the RF indicator red light comes on continuously (i.e.
use the same method as to enter House Code mode).
Release the button and the RF indicator red light will
ON/OFF Battery Switch
go out, indicating that the Remote Control Switch and
Smoke/CO alarms have exited House Code mode.
f) To remove other RadioLINK accessories from
House Code mode follow instructions as described in
their installation leaflets.
g) Fix the Remote Control Switch assembly to the
mounting box using the screws provided.
h) Using the Test switch, verify that the Remote
Control Switch activates all the alarms in the system
(If some or all of the alarms have not been activated,
then the House Coding procedure should be
repeated. If there are still some problems, see the
section 5 on "Troubleshooting").
Clearing the House Codes:
House Code Button
Figure 1
It may sometimes be necessary to clear the House
Codes (e.g. if you wanted to use the Remote Control
Switch with different alarms).
To clear the House Codes:
• Unscrew the Remote Control Switch assembly from
the mounting box.
• Press and hold the House Code button for over 6
seconds until the RF indicator red light turns on
continuously and then flashes slowly. Immediately
release the button and the RF indicator red light will
go out.
• Re-attach to the mounting box.
Note clearing the House Codes will now reset the
Remote Control Switch to the original factory setting.
It will now only communicate with un-coded alarms
(see base/smoke alarm instruction leaflet for
information on how to un-code the bases/smoke
alarms).
3. USING REMOTE CONTROL
Ei411H Remote Control Switch Functionality
1.When a RadioLINK smoke or heat alarm is
activated, the Fire light on the Remote Control switch
will flash rapidly for 2 minutes. After this period the
rate will change to one flash every 30 seconds and
will continue for 24 hours before turning off.
Ei412 Remote Control Switch Functionality
1.When a RadioLINK smoke or heat alarm is
activated, the Fire light on the Remote Control switch
3
will flash rapidly for 2 minutes. After this period the
rate will change to one flash every 30 seconds and
will continue for 24 hours before turning off.
2.When a RadioLINK Carbon Monoxide alarm is
activated, the Carbon Monoxide light on the Remote
Control Switch will flash rapidly for 2 minutes. After
this period the rate will change to one flash every 30
seconds and will continue for 24 hours before turning
off.
After 24 hours a previously sensed Fire/CO Alarm
can be indentified by using the alarm memory
function (see section 4).
What to do when the Alarms sounds
1.If there is a fire, immediately evacuate the premises
and telephone the fire brigade from outside.
If the Carbon Monoxide light is flashing, open doors &
windows while evacuating the premises. Telephone
the appropriate authorities to report a Carbon
Monoxide alarm has been activated.
2. When a Smoke/Heat alarm sounds and the cause
is not obvious, immediately press the 'Locate' switch.
This will silence all the alarms except those sensing
the fire.
3. Locate the alarm(s) sensing fire audibly.
careful, check doors are not warm and that there is no
sign of smoke before you open them (See escape
plan in Smoke Alarm instructions for further details).
4. If you are fully satisfied that there is no fire but the
Smoke/Heat alarm is still continuing to alarm then
press the 'Hush' switch.
The Remote Control Switch allows you to Locate,
Hush or Test units as follows:-
• Locate Switch – primarily used to identify the
Smoke/Heat/CO Alarm sensing fire/CO.
When all the alarms are sounding due to a fire/CO (or
nuisance alarm):
Press and release the spring loaded Locate switch.
The RF indicator red light will come on continuously
for 3 seconds to indicate that an RF signal is being
transmitted.
This will silence all the alarms except those sensing
Indicators
fire/CO.
This is a very useful feature. For example, consider
twelve alarms sounding simultaneously, then the unit
sensing the fire/CO can be identified audibly and the
premises evacuated or the problem quickly resolved.
• Hush Switch - used to silence nuisance alarms.
This should only be pressed after the Locate switch
Indicators
has been used to identify the Smoke/Heat/CO alarm
that triggered the system, and it is determined that no
fire or CO is present.
4
Be
5

Advertisement

loading

Summary of Contents for RadioLink Ei411H

  • Page 1 A16111-R4-EI411&412-UC-ENG 3/3/10 2:39 PM Page 1 on the Ei412 three red light indicators with flash in (However, this could result in problems with nearby will flash rapidly for 2 minutes. After this period the 1. INTRODUCTION Models: sequence. systems, if their units are being House Coded at the rate will change to one flash every 30 seconds and Ei411H For use with Ei168RC RadioLINK Bases (fitted with...
  • Page 2 If this product has become defective it must (i) Relocate the unit. control switch will also indicate if the source is Fire or be returned to Ei Electronics (see "Getting Your (iii) Relocate the Remote Control Switch and/or Carbon Monoxide. This feature is of great benefit in (ii) Increase the distance between the Remote Remote Control Switch Serviced") with proof of...