Power Error Messages - IBM 8677 - BladeCenter Rack-mountable - Power Supply Hardware Maintenance Manual And Troubleshooting Manual

Hardware maintenance manual
Hide thumbs Also See for 8677 - BladeCenter Rack-mountable - Power Supply:
Table of Contents

Advertisement

Power error messages

Note: See Chapter 7, "Parts listing, BladeCenter Type 8677 and 1881," on page 77 to determine which components
should be replaced by a field service technician.
Message
Power module 3 or 4 is required to
power blades 7 to 14
Power supply x fault
Power supply x 12V over voltage fault
Power supply x 12V over current fault
Power supply x 12V under voltage fault
Power supply x 12V current fault
Power supply x DC good fault
Power supply x removed
System over recommended voltage for
+12V
System over recommended voltage for
+1.8V
System over recommended voltage for
+2.5V
System over recommended voltage for
+3.3V
System over recommended voltage for
5V
System over recommended voltage for
+5V
System under recommended voltage for
+12V
System under recommended voltage for
+1.8V
System under recommended voltage for
+2.5V
System under recommended voltage for
3.3V
System under recommended voltage for
5V
Action
Ensure power modules 3 and 4 are installed and connected to ac
power.
Replace power module x.
Replace power module x.
1. An over current condition is typically caused by an external
load fault. Attempt to restart the faulted power module by
removing ac to the system components one at a time to isolate
the failing component.
2. Replace power module.
Replace power module x.
Replace power module x.
Replace power module x.
Reinstall power supply x.
1. Reseat the management module.
2. Reseat the power modules.
3. Replace the power modules.
4. Replace the management module.
1. Reseat the management module.
2. Replace the management module.
1. Reseat the management module.
2. Replace the management module.
1. Reseat the management module.
2. Replace the management module.
1. Reseat the management module.
2. Replace the management module.
1. Reseat the management module.
2. Replace the management module.
1. Reseat the management module.
2. Replace the management module.
1. Reseat the management module.
2. Replace the management module.
1. Reseat the management module.
2. Replace the management module.
1. Reseat the management module.
2. Replace the management module.
1. Reseat the management module.
2. Replace the management module.
Chapter 6. Symptom-to-FRU index
71

Advertisement

Table of Contents
loading

This manual is also suitable for:

Bladecenter eBladecenter e 8677Bladecenter e 1881

Table of Contents