Blade Server Error Messages; Kvm Error Message; I/O Module Error Messages - IBM 8677 - BladeCenter Rack-mountable - Power Supply Hardware Maintenance Manual And Troubleshooting Manual

Hardware maintenance manual
Hide thumbs Also See for 8677 - BladeCenter Rack-mountable - Power Supply:
Table of Contents

Advertisement

Note: See Chapter 7, "Parts listing, BladeCenter Type 8677 and 1881," on page 77 to determine which components
should be replaced by a field service technician.
Message
System is under recommended voltage
for +5V
System running nonredundant power

Blade server error messages

Note: See Chapter 7, "Parts listing, BladeCenter Type 8677 and 1881," on page 77 to determine which components
should be replaced by a field service technician.
Message
Blade server x was installed
Blade server x was removed
Received an [xxx] alert from an
unsupported ISMP type xxxx, via the
interconnect network

KVM error message

Note: See Chapter 7, "Parts listing, BladeCenter Type 8677 and 1881," on page 77 to determine which components
should be replaced by a field service technician.
Message
Error encountered switching KVM owner,
see system error log

I/O module error messages

Note: See Chapter 7, "Parts listing, BladeCenter Type 8677 and 1881," on page 77 to determine which components
should be replaced by a field service technician.
Message
Switch fault x
Switch module x was removed
Switch module x was installed
Switch module x was powered on
Switch module x was powered on
Switch System running nonredundant
switch modules
72
BladeCenter E Type 8677 and 1881: Hardware Maintenance Manual and Troubleshooting Guide
Action
1. Reseat the management module.
2. Replace the management module.
Ensure that power modules 1 and 2 are installed and operating
correctly. If blade servers are installed in bay 7 or higher, ensure
that power modules 3 and 4 are installed and working correctly.
Action
Information only. Take action as required.
Information only. Take action as required.
Ensure that all blade servers in the blade center are supported by
the management module.
Action
1. Reseat the blade server.
2. Reseat the management module.
3. Reflash the blade server H8 firmware.
4. Replace the blade server.
5. Replace the management module.
6. Replace the midplane.
Action
1. Reseat I/O module x.
2. Replace I/O module x.
Information only. Take action as required.
Information only. Take action as required.
Information only. Take action as required.
Information only. Take action as required.
Information only. Take action as required.