Watson-Marlow 620DuN and 620Du User Manual
When the language is chosen this menu will not appear again and all menus
will appear in the language you chose. (Language can be reset as described
later. See 18.19 Language.)
The pump displays the Watson-Marlow start-up screen for four seconds,
followed by the pump model identity screen for four seconds, and then the
manual mode main screen.
The rotation symbol on the display indicates clockwise rotation. The default
speed setting is 165rpm, but 265rpm is available (see 18.13 Set maximum
allowed speed). Other initial start-up operational parameters are listed in the
table below.
First-time start-up defaults
Language
Not set
Speed
165rpm
Direction
Clockwise
Pumphead
620R
Tube size
15.9mm
Calibration
620R 15.9mm tube
Backlight
On
Keypad lock
Off
Auto-restart
Off
Scaling
Off
Pump status
Stopped
Beeper
On
Manual screen rpm
Security code
Not set
Note: The settings shown above for Run, Clockwise rotation and Auto are those in
force on initial start-up for the functions available on Output 1, Output 2 and Output
3 respectively. For example, a high signal on Output 2 indicates clockwise rotation.
These can be changed later according to user requirements.
Note: High is equivalent to the common and normally open contacts of the relay on
the adapter board being closed.
The pump is now ready to operate according to the defaults listed above.
All operating parameters may be changed by means of key-presses. See 14 Manual
operation.
Analogue input
User trim
Remote stop
Pump number
Baud rate
Stop bits
Xon/Xoff
Scrolling increment
Output 1
Output 2
Output 3
Output 4
* Run
† Clockwise rotation
‡ Auto
4-20mA
None
Open=run
1
9600
2
Off
0.1rpm
Run/Stop *
Direction †
Auto/Man ‡
General alarm
= high
= high
= high
18