Default Catalyst 2955 Switch Alarm Configuration - Cisco 2950 - Catalyst Switch Configuration Manual

Software configuration guide
Hide thumbs Also See for 2950 - Catalyst Switch:
Table of Contents

Advertisement

Configuring Catalyst 2955 Switch Alarms
Configuring Catalyst 2955 Switch Alarms
This section describes how to configure the Catalyst 2955 switch alarms:

Default Catalyst 2955 Switch Alarm Configuration

Table 3-3
Table 3-3
Default Catalyst 2955 Switch Alarm Configuration
Alarm
Global
Power Supply Alarm
Primary Temperature Alarm
Secondary Temperature Alarm
Port
Link Fault Alarm
Port not Forwarding Alarm
Port is not Operating Alarm
FCS Bit Error Rate Alarm
Catalyst 2950 and Catalyst 2955 Switch Software Configuration Guide
3-4
SNMP Traps
SNMP is an application-layer protocol that provides a message format for communication between
managers and agents. The SNMP system consists of an SNMP manager, an SNMP agent, and a
management information base (MIB).
The snmp-server enable traps command can be modified in the Catalyst 2955 switch software to
allow the user to send alarm traps to an SNMP server. You can use alarm profiles to set
environmental or port status alarm conditions to send SNMP alarm traps. See the
Traps" section on page 3-11
Syslog Messages
You can use alarm profiles to send system messages to a syslog server. See the
Catalyst 2955 Switch Alarms" section on page 3-4
Default Catalyst 2955 Switch Alarm Configuration, page 3-4
Configuring the Power Supply Alarm, page 3-5
Configuring the Switch Temperature Alarms, page 3-6
Configuring the FCS Bit Error Rate Alarm, page 3-7
Configuring Alarm Profiles, page 3-9
Enabling SNMP Traps, page 3-11
shows the default Catalyst 2955 switch alarms configuration.
Default Setting
Enabled in switch single power mode. No alarm.
In dual power supply mode, the default alarm notification is a system
message to the console.
Enabled for switch temperature range 95
The primary switch temperature alarm is associated with the major relay.
Disabled.
Disabled on all interfaces.
Disabled on all interfaces.
Enabled on all interfaces.
Disabled on all interfaces.
for more information.
for more information.
Chapter 3
Configuring Catalyst 2955 Switch Alarms
"Enabling SNMP
"Configuring
0
C maximum to -20
o
C minimum.
78-11380-10