Configuring Rmon - Cisco 2950 - Catalyst Switch Configuration Manual

Software configuration guide
Hide thumbs Also See for 2950 - Catalyst Switch:
Table of Contents

Advertisement

Configuring RMON

Figure 26-1 Remote Monitoring Example
configured. SNMP configured.
The switch supports these RMON groups (defined in RFC 1757):
Because switches supported by this software release use hardware counters for RMON data processing,
the monitoring is more efficient, and little processing power is required.
Configuring RMON
This section describes how to configure RMON on your switch. It contains this configuration
information:
Catalyst 2950 and Catalyst 2955 Switch Software Configuration Guide
26-2
Network management station with
generic RMON console application
RMON alarms and events
RMON history
and statistic
collection enabled.
Workstations
Statistics (RMON group 1)—Collects Ethernet, Fast Ethernet, and Gigabit Ethernet statistics on an
interface.
History (RMON group 2)—Collects a history group of statistics on Ethernet, Fast Ethernet, and
Gigabit Ethernet interfaces for a specified polling interval.
Alarm (RMON group 3)—Monitors a specific MIB object for a specified interval, triggers an alarm
at a specified value (rising threshold), and resets the alarm at another value (falling threshold).
Alarms can be used with events; the alarm triggers an event, which can generate a log entry or an
SNMP trap.
Event (RMON group 9)—Determines the action to take when an event is triggered by an alarm. The
action can be to generate a log entry or an SNMP trap.
Default RMON Configuration, page 26-3
Configuring RMON Alarms and Events, page 26-3
Configuring RMON Collection on an Interface, page 26-5
Workstations
Chapter 26
Configuring RMON
78-11380-10