Using The Quick Arm (Optional); Changing Modes While System Armed; Disarming The System - GE NX-108E - Security NetworX NX-4 System User Manual

Networx series led keypad
Hide thumbs Also See for NX-108E - Security NetworX NX-4 System:
Table of Contents

Advertisement

Step 3
Press the [STAY] key.
The bypass light will illuminate indicating that all interior zones are bypassed. (All interior
devices will bypass automatically, giving the user freedom of movement within the interior
area.)
For each interior zone bypassed, the corresponding zone light will also illuminate. If any zone(s)
have been bypassed previously by the user, the light(s) corresponding to the bypassed zone(s)
will illuminate, alerting the user that a zone(s) may be unprotected and can be faulted without
an alarm.
The stay light will also illuminate. Note: normally, all entry/exit doors will be delayed.
Step 4
To change entry/exit to "Instant", press the [STAY] key again.
The instant light will illuminate indicating that the entry/exit doors have no delay.
To change entry/exit to "Delayed", press the [STAY] key again.
The instant light extinguish indicating that the entry/exit doors are delayed.

Using the Quick Arm (optional)

The Quick Arm feature may be used if it is enabled. Quick Arm will allow the user to arm the security system without
entering a user code. Quick Arm in the AWAY mode is possbile by pressing the [EXIT] key. The system can be quick
armed in the STAY mode by pressing the [STAY] key. This feature is used for ARMING ONLY, and will not disarm the
security system. This is ideal for a maid or baby sitter code, etc.

Changing modes while system armed

Step 1
Pressing the [STAY] key will turn on/off (toggle) a delay on Entry/Exit doors and turn on/off (toggle) the
instant light.
Step 2
Press the [BYPASS] key at this time to turn on/off (toggle) all designated interior zones.
This is only possible if programmed by your installer ("bypass toggle" option set).
Step 3
When armed, pressing the [EXIT] key will start the Exit delay, enabling you to leave the building.
This is only possible if programmed by your installer ("re-exit" option set).
The instant light needs to be off at this time if you plan on re-entering the building, otherwise you will create an
alarm. You may re-initiate an entry/exit delay by pressing the [STAY] key again. The instant light will go out.

Disarming the system

When you enter the protected area through one of the designated Entry/Exit doors, the keypad control will
sound a solid tone for the duration of the entry delay time, or until you enter a valid code. After entering a
valid code, the red armed light will go off and the tone will stop. The security system is now DISARMED. If a
valid code is not entered before the end of the entry delay, an alarm will occur.
(NOTE: If the red armed light is flashing during the entry delay, the alarm system has been activated in
your absence. Leave the building immediately and call your alarm company and/or the police from a
safe location.)
NX-108/116/124E User manual
IMPORTANT!
Page 10
10/11/05

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents