FO-3150U/C
6 Remove two screws.
7 Pull DV bias electrode toward you, and remove it from the lower
frame.
Fig. 49
Note for assembly
When attaching DV bias electrode, adjust so that the contact is over
the DC-bias electrode of the PWB unit.
Fig. 50
Note
Fusing section:
When fixing the cable of the temperature fuse and the thermistor, put it
neat inside the projection of the frame.
If not, paper jams may be resulted.
Fig. 51
DV bias electrode
7
6
Terminal
3 – 26
Optical section
Do not touch the mirror fixing screw in the optical section. If touched,
the mirror bracket may be change, causing a shift in the print image
position or vague images. The mirror angle cannot be adjusted in the
market.
Do not touch the volume attached. If touched, normal images cannot
be produced. This adjustment cannot be made in the market.
< Don't touch >
< Don't touch >
< Don't touch >
Fig. 52
33. Wire treatment
Panel Unit
Motor cable
Core
Fig. 53
< Don't touch >
Panel cable
CIS cable
Core

Advertisement