3. IC protectors replacement
ICPs (IC Protectors) are installed to protect the TX motor drive circuit
and verification stamp drive circuit. ICPs protect various ICs and elec-
tronic circuits from an overcurrent condition.
The location of ICPs are shown below:
(1) FU100 is installed in order to protect IC's from and overcurrent gen-
erated in the verification stamp drive circuit. If FU100 is open, re-
place it with a new one.
4. Settings
(1) Dial mode selector
OPTION SETTING: DIAL MODE (Soft Switch No. SW2 DATA No. 1)
Use this to set the fax machine to the type of telephone line you are on.
• The factory setting is "TONE".
(step 1) Select "OPTION SETTING".
FUNCTION
KEY:
DISPLAY:
OPTION SETTING
KEY:
(step 2) Select "DIAL MODE".
Push
until " DIAL MODE " is
KEY:
indicated because the number of
s changes by the models and press
DISPLAY:
1= TONE, 2= PULSE
(step 3) Select, using "1" or "2".
KEY:
1
DISPLAY: TONE SELECTED
KEY:
2
DISPLAY:
PULSE SELECTED
(step 4) End, using the "STOP" key.
KEY:
STOP
key.
2 – 3
CNPRT
CNRTH
CNFUSE
CNFAN
CNMT
FU100
IC1
Control PWB (Bottom side)
Fig.5
FO-3150U/C
CNPRG
CNSP
CNPN
CNLIUA
CNCIS