DISKINFO
Returns device revision information.
Syntax
diskinfo
Description
This command returns basic revision information about the controller and all recognized disks
within the selected array. Additional revision information might be available using the inquiry
command.
The storage type (Map/User column) indicates if the disk is used for user data storage (US), meta
data storage (MS) (Map Disk), or both. The EID column shows the enclosure ID. An asterisk (*) in
the Disk Slot column indicates the selected disk slot.
Example
VADIAG> diskinfo
Loop
Fru
Pair
EID
------- ----- ---
M/D7
255
0
M/D1
255
0
M/D3
255
0
M/D5
255
0
JA0/D1
0
0
JA0/D2
0
0
JA0/D3
0
0
JA0/D5
0
0
JA0/D7
0
0
M/D9
255
0
M/D13
255
0
M/D14
255
0
DISKINFO
12
Disk
Map/
Slot
User
Vendor ID Product ID
----
----- --------- ------------ ----- ---------
22
US/MS HP 18.2G
16
US/MS HP 18.2G
18
US
HP 18.2G
20
US
HP 18.2G
0
US
HP 18.2G
1
US
HP 18.2G
2
US
HP 18.2G
4
US
HP 18.2G
6
US
HP 18.2G
24
US
HP 18.2G
28
US
HP 36.4G
29
US
HP 18.2G
Rev
ST318451FC
HPC4
ST318451FC
HPC4
ST318451FC
HPC4
ST318451FC
HPC4
ST318451FC
HPC4
ST318451FC
HPC4
ST318451FC
HPC4
ST318451FC
HPC4
ST318451FC
HPC4
ST318451FC
HPC4
ST336704FC
HPC3
ST318451FC
HPC4
Capacity
17089 MB
17089 MB
17089 MB
17089 MB
17089 MB
17089 MB
17089 MB
17089 MB
17089 MB
17089 MB
34179 MB
17089 MB