Download Print this page

HP StorageWorks 7110 - Virtual Array Using Manual page 10

Using vadiag on hp-ux
Hide thumbs Also See for StorageWorks 7110 - Virtual Array:

Advertisement

DISPMAP
Displays the device map.
Syntax
dispmap
Description
This command displays a list of all the array controllers found on the system. The list includes the
following fields:
Array Indx. Device index number which is used by other VADIAG commands to reference a
specific array controller. An asterisk (*) next to this field indicates this controller is selected for
testing.
Path. Logical path to each array. The path construct is the same as the PDC and MAPPER's
path. An array with dual controllers has two different logical paths. Therefore, two different
device index numbers will access the same array.
Product ID. Product identification. This is what MAPPER displays as the product string.
Rev. The disk drive's firmware revision.
Size. The approximate size of the LUN in either megabytes (MB), gigabytes (GB), or terabytes
(TB). The size of the LUN might not match the information specified by the vendor because of
differences in calculation methods.
Example
VADIAG> dispmap
Array
Indx
Path
----
---------------------
* 0
8/4.8.0.108.0.0.0
DISPMAP
10
Product ID
---------------------------
HP A6188A Disk Array (Ctrl)
Rev
Size
----- ------
HP01
10 GB