Capturing A Configuration; Using An Input Script - HP ProLiant DL320e User Manual

Hp scripting toolkit 9.30 for windows user guide
Hide thumbs Also See for ProLiant DL320e:
Table of Contents

Advertisement

For more information, see the Configuring Arrays on HP Smart Array Controllers Reference Guide
on the HP website at http://www.hp.com/support/CASAC_RG_en.
Users familiar with the previous versions of ACU Scripting must now install the ACU CLI application
to obtain the scripting executable. The new ACU scripting executable (hpacuscripting) replaces
the former executable (cpqacuxe) in all scripts.
The ACU Scripting application has two scripting modes:
Capture mode for capturing a configuration
ACU inspects the configuration of all internal and external array controllers connected to the
server and then writes a script file describing this configuration.
Input mode for using an Input script
ACU reads the array configuration described in a specified script file. See
script file" (page
NOTE:
For a complete list of all command-line parameters, execute the /? utility.

Capturing a configuration

To capture the configuration of a system, enter the following command at the system command
line prompt:
hpacuscripting -c [drive:][path] OUTPUTFILENAME.ext [-internal |
-external] -e [drive:][path]ERRORFILENAME.ext
OUTPUTFILENAME is the name of the capture file, and ext. is the file extension. If you do not
specify a name and location for this file, ACU uses the default name ACUOUTPUT.ini and places
the file in the ACU working directory.
The -internal and -external switches limit capture to internal or external controllers.
The -e switch information is used only if ACU must generate an error file. By default, ACU names
the error file ERROR.ini and places it in the ACU working directory.

Using an Input script

To use an Input script to configure or reconfigure a system, first locate a suitable ACU script or see
"Creating an ACU script file" (page
Then, enter the following command at the system command line prompt:
hpacuscripting -i [drive:][path]FILENAME.ext [-internal | -external]
[-reset] -e [drive:][path]ERRORFILENAME.ext
FILENAME is the name of the ACU input file, and ext is the file extension. If you do not specify
the name and location of this file, ACU searches for ACUINPUT.ini in the ACU working directory.
The -internal and -external switches limit configuration operations to internal or external
controllers.
The -reset flag destroys any existing data and overwrites the current configuration with the
configuration specified in the script.
The -e switch information is used only if ACU must generate an error file. By default, ACU names
the error file ERROR.ini and places it in the ACU working directory.
30
Scripting Toolkit utilities
31). ACU then applies this configuration to a target system.
31).
(page 30)
(page 30)
"Creating an ACU

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents