Sspadapterswithaccess; Stripesize; Hba Category; Connectionname - HP ProLiant DL320e User Manual

Hp scripting toolkit 9.30 for windows user guide
Hide thumbs Also See for ProLiant DL320e:
Table of Contents

Advertisement

array, as long as the operating system supports logical drive extension. You cannot reduce the
size of the logical drive.
CAUTION:

SSPAdaptersWithAccess

Enter values here to identify the SSP adapters that you want to have access to a logical drive. The
values are processed only if either SSPState or LogicalDriveSSPState is set to Enable. Otherwise,
the values are ignored.
NOTE:
Be sure that every HBA in the system has access to the logical drives for which multi-path
will be used.

StripeSize

You can enter a numerical value for this option to specify the size of the data stripes (in kilobytes),
or you can leave this option blank and allow ACU to use a default value.
The valid stripe size values depend on the RAID level.
For RAID 0, RAID 1, or RAID 1+0 arrays, you can enter any of the stripe size values listed in
the sample script.
For RAID 5 arrays, the maximum stripe size in most cases is 256 KB, but old controller models
are often limited to 64 KB.
For RAID 6 arrays, the maximum stripe size is either 64 KB or 256 KB, depending on the
controller.
The default stripe size value depends on the action mode.
In Configure action mode, the default value is determined by the RAID level that you specified
earlier in the script. In some cases, it also depends on the ACU version, the controller model,
and the controller firmware version.
For RAID 0, RAID 1, or RAID 1+0, the default value is 128 KB.
For RAID 5, the default value is usually 64 KB, but on some controller models it is 16 KB
or 128 KB.
For RAID 6, the default value is usually 16 KB, but on some controller models it is 64 KB
or 128 KB.
In Reconfigure action mode, the default value for this option is the stripe size that is already
configured for the logical drive. If you enter a value that is different from the existing stripe
size, ACU attempts to migrate the logical drive to the stripe size that you specify. (If you intend
to migrate the logical drive, back up all data before starting the migration procedure.)

HBA category

The HBA category has the following options:
"ConnectionName" (page 40)
"HBA_WW_ID" (page 41)
"HostMode" (page 41)

ConnectionName

This option is a user-defined string used as the connection name for the specified HBA.
40
Scripting Toolkit utilities
Back up all data before extending a logical drive.