Error code
Error message
2851
Invalid RAID Array ID.
2852
Invalid SSP state.
2853
Cannot change SSP settings.
2854
Invalid SSP adapter ID.
2855
Controller does not support logical drive
SSP states. Use the SSPState controller
command to set the controller SSP state.
2856
Controller does not support controller SSP
state. Use the LogicalDriveSSPState logical
drive command to set SSP states for each
logical drive.
2857
Invalid surface scan delay.
2861
Controller does not support redundancy
settings.
2864
Invalid preferred path mode.
2865
Invalid preferred path.
2866
Failure opening capture file <text>.
2867
Failure opening input file <text>.
2868
Failure opening error file <text>.
2869
<text> command expected.
2870
<text> is not a supported command.
2871
<text> is not a Controller command.
2872
<text> is not an Array command.
2873
<text> is not a Logical Drive command.
2874
<text> is not an HBA command.
2875
More than one <text> command cannot
exist in the same section.
2876
Invalid physical drive count.
2877
No spares available.
2878
Spare request for RAID 0 is invalid.
2879
Reset and reconfigure combined error.
2880
Invalid drive type specified.
44
Scripting Toolkit utilities
Comment or clarification
The scripted RAID Array ID is invalid. Use characters from
the set a–z, A–Z, 0–9, !, @, #, *, (, ), ,, -, _, +, :, ., /, and
[space]. The ID cannot end with a space character or exceed
the maximum number of characters allowed by the controller.
The controller is not redundant or does not support
redundancy settings.
The specified value for the preferred path mode is not valid,
or the controller is not available.
The specified preferred path is not a valid chassis slot for an
available active controller, or the controller is not available.
The <text> command is missing or in the wrong place in the
script file.
The <text> command does not belong in the Controller section
of the script file.
The <text> command does not belong in the Array section
of the script file.
The <text> command does not belong in the Logical Drive
section of the script file.
The <text> command does not belong in the HBA section of
the script file.
The script specifies more drives than are available of the
specified drive type.
No drives were found that could be used as spares for the
specified array.
RAID 0 does not support spares.
A controller reset with data loss was specified while in
Reconfigure mode.