Error code
Error message
1091
Controller does not support SSP.
1093
Controller requires physical drives to set
license keys.
1 102
Slot information is not available.
1 1 10
Controller does not support license keys.
1 1 1 1
Invalid license key.
1 1 12
Controller has maximum number of license
keys.
1 1 14
Controller requires non-failed physical
drives to set license keys.
2564
Controller is locked by another machine or
user.
2818
Invalid Method.
2819
Invalid Controller.
2820
Could not detect controller <text>.
2821
No controllers detected.
2822
Invalid read cache/write cache ratio.
2823
Invalid rebuild priority.
2824
Invalid expand priority.
2825
Invalid array.
2826
Array not specified.
2827
New array ID does not match the next
available array ID.
2828
New array ID already exists.
2829
Cannot create array.
2830
Cannot expand array.
42
Scripting Toolkit utilities
Comment or clarification
between operations. Limit the number of such configuration
changes in the script.
You cannot run a script in Input mode on internal controllers
that do not have slot information online. Systems running
Microsoft Windows must have the System Management Driver
loaded.
The scripted Method value is not valid.
The scripted controller does not match any existing controllers.
This error applies to Input mode only. If no controllers are
detected in Capture mode, the capture file is empty.
The specified cache ratio is not supported by either the
controller or the current controller configuration.
This error message appears if the expand priority value
specified in the script is not supported. This message also
appears if expansion is not possible because the Expand
Priority feature is then not supported. Expansion might be
temporarily unavailable on a controller that normally supports
expansion if, for example, the cache battery has low charge,
another expansion or migration is already in progress, or the
array has the maximum supported number of physical drives.
The array ID is invalid.
The script file has commands that require an array, but no
array is specified.
The scripted array ID is not the next ID in sequence, based
on the IDs of the existing arrays. For example, only array A
exists and the script file specifies creation of array C (omitting
array B).
This error occurs in Configure mode when the array ID
specified in the script file already exists in the configuration.
In Configure mode, you can create only new arrays.
The controller has no unassigned physical drives, or it already
has the maximum number of arrays or logical drives.
The controller does not support expansion, or the current
controller configuration is not expandable.