The options for each category are listed in the following table and described in more detail in the
remainder of this section.
Category
Options
Control
Action
Method
Controller
Controller
ChassisName
ClearConfigurationWithDataLoss
DeleteLicenseKey
DPOEnable
ElevatorSortEnable
ExpandPriority
IRPEnable
LicenseKey
MNPDelay
PreferredPathMode
QueueDepth
ReadCache
RebuildPriority
SSPState
SurfaceScanDelay
WriteCache
Array
Array
Drive
DriveType
OnlineSpare
Logical
ArrayAccelerator
Drive
LogicalDrive
LogicalDriveSSPState
ParityGroups
PreferredPath
RAID
Sectors
Size
SSPAdaptersWithAccess
StripeSize
HBA
ConnectionName
HBA_WW_ID
HostMode

Control category

The Control category has the following options:
"Action mode" (page 34)
"Method mode" (page 34)
Description
Use these options to define the overall behavior of ACU when it processes
scripts and creates configurations. Control options can occur only once in
a script file and must be listed first.
Use these options to specify the controller you are configuring (or the
controller that had its configuration captured). Although the Controller
option must begin this section of the script, you can script other options in
this category in any order.
You can use one script file to configure all controllers in a system, and you
can configure the controllers identically or individually. If you define each
controller configuration individually, enter the option values for one
controller and its arrays and logical drives before specifying the option
values for another controller.
Use these options to describe an array you are configuring on the controller
previously specified in the script. (If no controller was previously specified,
ACU stops processing the script and creates an error file.) Although the
Array option must begin this section of the script, you can script the other
options in this category in any order.
Use these options to describe a logical drive you are configuring on an
array previously specified in the script. (If no array was previously
specified, ACU stops processing the script and creates an error file.)
Although the LogicalDrive option must begin this section of the script, you
can script the other options in this category in any order.
Use these options to specify an HBA you are configuring.