HP D5970A - NetServer - LCII Configuration Manual page 82

Microsoft cluster for server with hp rack storage/12, hp rack storage/8 & hp netraid-3si adapter
Hide thumbs Also See for D5970A - NetServer - LCII:
Table of Contents

Advertisement

array is less than the total capacity of all drives in the array. The useable array capacity
will be C(N-1), where N is the number of drives and C is the capacity of one drive.
3.
Click Advanced and set the Write Policy to Write Thru. Click OK.
4.
If you are creating a RAID 5 array, press Accept. If you are creating a RAID 50 array, check the
Span Arrays box, then press Accept.
5.
If you:
want to define another array, click Back and repeat the steps listed in "Define an Array" above
starting with step 3.
have identified all your arrays, click Next, Finish, and then OK.
NetRAID Assistant saves the array configuration and prompts that the array configuration has
changed. Click OK.
Initialize the Array
After you have defined the cluster's arrays, initialize the arrays you defined. HP NetRAID Assistant
initializes all arrays you have defined at the same time.
To initialize the arrays:
1.
Click OK at the Would you like to Initialize? prompt.
HP NetRAID Initialization may be time consuming.
2.
When initialization is complete, exit HP NetRAID Assistant.
NetRAID Supplement to the HP NetServer Microsoft Cluster Installation Guide
23

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents