Shared Storage Hardware Setup; Hp Rack Storage/12 Setup - HP D5970A - NetServer - LCII Configuration Manual

Microsoft cluster for server with hp rack storage/12, hp rack storage/8 & hp netraid-3si adapter
Hide thumbs Also See for D5970A - NetServer - LCII:
Table of Contents

Advertisement

3 Shared Storage Hardware Setup

This section includes instructions for setup of three types of shared storage devices. Follow the instructions
for the type(s) of devices that you are using in your cluster. See the Configuration Guide for allowed shared
storage devices that can be used in your cluster.
HP Rack Storage/12
HP Rack Storage/8
HP Storage System/6

HP Rack Storage/12 Setup

Set Configuration Switches
Set the configuration switches as shown below:
Install Additional Controllers
For use as shared storage in a cluster, each Rack Storage/12 must have two SCSI controllers. Install a second
SCSI controller (D6025A) in each Rack Storage/12. Follow the instructions supplied with the Controller for
installation.
to part "4 Cluster Cabling and Setup" in the Installation Guide or setup another share storage
device such as the Rack Storage/8.
NetRAID Supplement to the HP NetServer Microsoft Cluster Installation Guide
Configuration Switches:
1 - Cluster Operations, set Right
2 - Reserved - any position
3 - Reserved - any position
4 - Reserved - any position
Switches 2-4 shown in default
position.
HP Rack Storage/12 Cluster Configuration
Left
Right
1
2
3
4