Setup Raid 1 And 10 Arrays - HP D5970A - NetServer - LCII Configuration Manual

Microsoft cluster for server with hp rack storage/12, hp rack storage/8 & hp netraid-3si adapter
Hide thumbs Also See for D5970A - NetServer - LCII:
Table of Contents

Advertisement

From the Windows NT Start menu, click Programs|NetRAID|NetRAID Assistant.
The HP NetRAID Assistant program loads and displays its main window.
HP NetRAID Assistant lists the Physical Devices (actual physical drives) and Logical Devices (RAID arrays)
on the NetRAID Assistant screen. The Physical Devices heading lists the drives in columns by channel.
Some clusters do not use channel 2 and so no devices will be listed. Likewise, some clusters only use one
channel and so both channels 1 and 2 will be devoid of entries.
To view the properties of a physical or logical device listed, double-click the device. The number in
parentheses to the right of each physical drive icon is its SCSI ID. The state of each physical drive appears to
the right of the SCSI ID. Initially the device will be described as READY. The possible states of a physical
drive are as follows:
The state...
Onln
Rdy or READY
HOTSP
FAILED
REBUILDING
Refer to the HP NetRAID User Guide in Information Assistant for more information about HP NetRAID
Assistant.

Setup RAID 1 and 10 Arrays

Each RAID 1 disk array is composed of two hard (hot swap) drives located in external shared storage
cabinets. RAID level 1 (mirroring) provides storage redundancy with maximum performance. A RAID 1
array consists of two drives that contain exactly the same data. That is, all of the data on one drive is
replicated (mirrored) on the other. Since each drive contains a complete copy of all data, all data is still
NetRAID Supplement to the HP NetServer Microsoft Cluster Installation Guide
HP NetRAID Assistant Screen
Indicates the drive is...
Online, functioning normally, and part of a configured array.
Functioning normally, but not part of a configured logical drive nor configured
as a hot spare.
Configured as a hot spare, powered up and ready for use.
Out of service because a fault occurred.
Rebuilding an array on a new drive.
19

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents