4.
Select one or more of the relevant enclosures and click the >> symbol to add them to the rack. You can
click << to remove enclosures from the rack.
Note:
indicates enclosures which are daisy chained.
5.
Click Save. The enclosure is added to the rack and the picture of the new rack with the added enclosure
appears. If an enclosure has already been added to another rack, a message appears indicating the
enclosure is already assigned to another rack. You can confirm your intention to remove the enclosure
from the existing rack and it is added to the new rack.

Saving an Onboard Administrator configuration

You can save the current settings of a c-Class enclosure as a configuration script. After you save this
configuration file, you can always upload this configuration script using the Onboard Administrator to revert
to the previous settings of the enclosure. When you save a configuration file, you must provide a file name
that is unique to that enclosure. Also, you can save multiple configuration scripts for a single c-Class enclosure.
To save a c-Class enclosure configuration:
1.
From the Tools and Links page of the Onboard Administrator, click Save/Restore Configuration
of Onboard Administrator.
Note: You can access this option from Save or Restore Onboard Administrator settings in the
Configure section.
2.
Enter the user name and password for the Onboard Administrator. The Save/Restore Configuration
Script page appears.
3.
Enter a unique name for the configuration script and click Save. The name must meet the following
conditions:
Alphanumeric and can contain special characters such as underscores and periods.
Must start with an alphabet character.
The configuration script is listed in the Restore Configuration section.

Restoring an Onboard Administrator configuration

You can restore the previous settings of an enclosure by selecting the respective configuration script that you
had saved earlier.
To restore a c-Class enclosure configuration:
1.
From the Tools and Links page of the enclosure, click Save/Restore Configuration of Onboard
Administrator.
2.
Enter the user name and password for the Onboard Administrator. The Save/Restore Configuration
Script page appears.
3.
In the Restore Configuration section, select the file that includes the configuration settings that you
want to restore.
4.
Click Restore. The settings of the enclosure are restored.

Deleting a configuration script

You can delete a configuration script.
To delete a c-Class enclosure configuration:
1.
From the Tools and Links page of the enclosure, click Save restore OA configuration and select
the configuration script to be deleted and click Delete.
Note: You can select multiple configurations and delete them simultaneously.
2.
Click Back from the browser to navigate to the Tools/Links page of the Onboard Administrator.
Viewing enclosures