Saving and Restoring Monitor Configuration

You can use the perfCfgSave command to save the current end-to-end and
filter monitor configuration settings into flash memory. This command enables the
performance monitoring configuration to be saved over power cycles. You can use
the perfCfgRestore command to restore the saved monitor configuration
from flash memory.
For example, if you power cycle the switch, and you want to use the same
end-to-end and filter monitoring configuration that was in effect prior to the power
cycle, do the following:
1. Use the perfCfgSave command to save the monitor configuration
2. Power cycle the switch.
3. Use the perfCfgRestore command to restore the saved monitor
Example 1.
Use the perfCfgClear command to clear the previously saved performance
monitoring configuration settings from flash memory.
Example 2.
Advanced Performance Monitoring Version 3.1.x/4.1.x User Guide
settings.
configuration.
sw1:admin> perfCfgSave
This will overwrite previously saved Performance Monitoring
settings in FLASH ROM.
Please wait ...
Committing configuration...done.
Performance monitoring configuration saved in FLASH ROM.
sw1:admin> perfCfgRestore
This will overwrite current Performance Monitoring
settings in RAM.
Please wait ...
Performance monitoring configuration restored from FLASH ROM.
sw1:admin> perfCfgClear
This will clear Performance Monitoring settings in FLASH ROM.
The RAM settings won't change.
[y|n]y
Please wait ...
Committing configuration...done.
Performance Monitoring configuration cleared from FLASH.
Using Advanced Performance Monitoring
Do you want to continue? [y|n]y
Do you want to continue? [y|n]y
Do you want to continue?