POST Error Code
1117
Failed baud rate test
1162
Serial port configuration error
11XX
Not listed above
1201
1202, 1206, 1208, 1209, 12XX
1207
13XX
1402
Printer not ready
1403
No paper error, or interrupt failure
1404
System board timeout failure
1405
Parallel adapter error
1406
Presence test error
14XX
Not listed above. Check printer before
replacing system board
15XX
1692
Boot sequence error
16XX
1762
Hard disk drive configuration error
1780 (Disk Drive 0)
1781 (Disk Drive 1)
1782 (Disk Drive 2)
1783 (Disk Drive 3)
FRU/Action
1. Run Enhanced Diagnostics
1. Run Configuration
2. Serial Adapter
(if installed)
3. System Board
1. System Board
1. System Board
2. Any Serial Device
1. Dual Async Adapter/A
2. System Board
3. Any Serial Device
1. Communications Cable
2. Dual Async Adapter/A
1. Game Adapter
Information only
Information only
1. Run Enhanced Diagnostics
1. Run Enhanced Diagnostics
1. Run Enhanced Diagnostics
1. Printer
2. System Board
1. SDLC Adapter
1. Run FDISK to ensure at least one active
partition is set active
1. 36/38 Workstation Adapter
1. Run Configuration. (See "Setup Utility
program" on page 12.)
1. Hard Disk Drive
2. System Board
3. Riser card
4. Hard Disk Cable
5. Power Supply
Chapter 7. Symptom-to-FRU Index