IBM NetVista Hardware Maintenance Manual page 56

Hardware maintenance manual for netvista 2289 and 6824 systems
Hide thumbs Also See for NetVista:
Table of Contents

Advertisement

50
Hardware Maintenance Manual
Diagnostic Error Code
014-001-XXX
Parallel port Presence
014-002-XXX
014-003-XXX
Parallel port Timeout/Parity error
014-013-XXX
014-014-XXX
Parallel port Control Signal/Loopback test
failure
014-015-XXX
Parallel port External Loopback failure
014-027-XXX
Parallel port Configuration/Setup error
014-03X-XXX
014-04X-XXX
Parallel port failure
014-195-XXX
Parallel port Test aborted by user
014-196-XXX
Parallel port test halt, error threshold
exceeded
014-197-XXX
Parallel port test warning
014-198-XXX
Parallel port test aborted
014-199-XXX
Parallel port test failed, cause unknown
014-2XX-XXX
014-3XX-XXX
Parallel port failure
015-000-XXX
USB port Interface Test Passed
015-001-XXX
USB port Presence
FRU/Action
1. Remove external parallel device, if
present
2. Run setup, enable port
3. System board
1. System board
1. System board
1. Wrap plug
2. System board
1. Run Setup, enable port
2. Flash the system
3. System board
1. System board
1. Information
2. Re-start the test, if necessary
1. Press F3 to review the log file
2. Re-start the test to reset the log file
1. Make sure the component that is called
out is connected and/or enabled
2. Re-run test
3. Component that is called out in warning
statement
4. Component under test
1. If a component is called out, make sure
it is connected and/or enabled
2. Flash the system and re-test
3. Go to the "Undetermined problems"
section
1. Go to the "Undetermined problems"
section
2. Flash the system and re-test
3. Replace component under function test
1. External parallel device
2. System board
1. No action
1. Remove USB device(s) and re-test
2. System board

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

22896824

Table of Contents