CR
Module
Level
CR00013243
Core
CR00013279
OSPF
CR00013353
Switch
CR00013421
BGP
CR00013538
IP Gateway
Version 281-01
C613-10482-00 REV A
3
The system LED did not indicate when an internal power supply fault occurred.
This issue has been resolved. The system LED now flashes 3 times to indicate a
fault. Also, output of the show system command now reports voltages more
accurately.
3
When a user changed the OSPF priority of an interface, the router or switch did
not immediately perform the process to elect a Designated Router and Backup
Designated Router (BDR).
This issue has been resolved.
3
Certain BIST and AUTOBURNIN tests reported errors, especially if an IPv6
accelerator was installed. Also, if a user entered the commands disable or
enable switch learning and an IPv6 accelerator was installed, the switch
displayed an error message that said:
"SWI ERROR: (1) swmxMacLearningSet [1] - Unable to set learning"
These issues have been resolved.
3
When a user created a BGP module trigger for the peerstate event, the router
or switch did not allow specification of the script or state parameters.
This issue has been resolved. All such generic parameters are now available with
module-specific triggers.
3
Software Version 2.8.1 introduced a new msgtype parameter for the command
add igmp filter, which enables users to filter on IGMP query, report or leave
messages. This parameter was mistakenly made compulsory. Therefore, if an
existing configuration script contained IGMP filters, and the router or switch
restarted with that configuration, the filters did not work.
This issue has been resolved. The msgtype parameter is now optional, with a
default of report.