Cabletron Systems 9F426-03 User Manual

Fddi switch module
Hide thumbs Also See for 9F426-03:

Advertisement

Quick Links

SmartSwitch 9000
9F426-03
User's Guide
903number

Advertisement

Table of Contents
loading

Summary of Contents for Cabletron Systems 9F426-03

  • Page 1 SmartSwitch 9000 9F426-03 User’s Guide 903number...
  • Page 3 Notice Notice Cabletron Systems reserves the right to make changes in specifications and other information contained in this document without prior notice. The reader should in all cases consult Cabletron Systems to determine whether any such changes have been made. The hardware, firmware, or software described in this manual is subject to change without notice.
  • Page 4: Fcc Notice

    Notice FCC Notice This device complies with Part 15 of the FCC rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. NOTE: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC rules.
  • Page 5 Notice DOC Notice This digital apparatus does not exceed the Class A limits for radio noise emissions from digital apparatus set out in the Radio Interference Regulations of the Canadian Department of Communications. Le présent appareil numérique n’émet pas de bruits radioélectriques dépassant les limites applicables aux appareils numériques de la class A prescrites dans le Règlement sur le brouillage radioélectrique édicté...
  • Page 6: Safety Information

    Notice Safety Information CLASS 1 LASER TRANSCEIVERS The FPIM-05 and FPIM-07 are Class 1 Laser Products CLASS 1 LASER PRODUCT The FPIM-05 and FPIM-07 use Class 1 Laser transceivers. Read the following safety information before installing or operating these adapters. The Class 1 laser transceivers use an optical feedback loop to maintain Class 1 operation limits.
  • Page 7 Notice Safety Information CLASS 1 LASER TRANSCEIVERS Laser Radiation and Connectors When the connector is in place, all laser radiation remains within the fiber. The maximum amount of radiant power exiting the fiber (under normal conditions) is -12.6 dBm or 55 x 10 watts.
  • Page 8: Declaration Of Conformity

    Notice DECLARATION OF CONFORMITY Application of Council Directive(s): 89/336/EEC 73/23/EEC Manufacturer’s Name: Cabletron Systems, Inc. Manufacturer’s Address: 35 Industrial Way PO Box 5005 Rochester, NH 03867 European Representative Name: Mr. J. Solari European Representative Address: Cabletron Systems Limited Nexus House, Newbury Business Park London Road, Newbury Berkshire RG13 2PZ, England Conformance to Directive(s)/Product Standards:...
  • Page 9: Table Of Contents

    Contents Chapter 1 Introduction Features........................... 1-1 Related Manuals......................1-4 Getting Help ........................1-4 Chapter 2 Installing the SmartSwitch 9000 Module Unpacking the Module....................2-1 Installing an FPIM......................2-1 User Accessible Components ..................2-2 Installing the Module into the SmartSwitch 9000 Chassis........2-5 The Reset Switch ......................
  • Page 10 Contents Appendix A FPIM Specifications FPIM-00 and FPIM-01....................A-1 FPIM-02 and FPIM-04....................A-2 FPIM-05 and FPIM-07....................A-3 viii...
  • Page 11: Chapter 1 Introduction

    Chapter 1 Introduction ® The 9F426-03 FDDI SmartSwitch Module, shown in Figure 1-1, is a four port switch module with three front panel FDDI interfaces and one INB-2 backplane interface. The external FDDI networks are connected to the module using standard Cabletron FPIMs on the front panel.
  • Page 12 Introduction Cabletron enterprise MIBs. In addition, the front panel provides LEDs for FDDI link status per port, as well as transmit and receive activity. Full Duplex The 9F426-03 may be configured to operate in either Simplex or Full Duplex mode. This is selected though local management or via SNMP. Connectivity The 9F426-03 module has one interface to the INB-2 and three front panel FDDI interfaces.
  • Page 13 Introduction FDDI 9F426-03 Figure 1-1. The 9F426-03 Module...
  • Page 14: Related Manuals

    Introduction Related Manuals The manuals listed below should be used to supplement the procedures and technical data contained in this manual. SmartSwitch 9000 Installation Guide SmartSwitch 9000 9C300-1 Environmental Module User’s Guide SmartSwitch 9000 9C214-1 AC Power Supply User’s Guide INB Terminator Modules Installation Guide SmartSwitch 9000 Module Local Management User’s Guide Getting Help...
  • Page 15: Installing The Smartswitch 9000 Module

    Chapter 2 Installing the SmartSwitch 9000 Module This module uses FPIMs for the front panel connections. They are not shipped with the module and must be purchased separately. For more information on FPIMs, see Appendix A . Unpacking the Module 1.
  • Page 16: User Accessible Components

    Installing the SmartSwitch 9000 Module Figure 2-1. Installing an FPIM User Accessible Components Figure 2-2 shows the various components that are accessible to the user. These consist of an eight-position DIP switch (explained below), replaceable PROMs and sockets for RAM. These will be used for future upgrades. Instructions for installing the components will be supplied with the upgrade kit.
  • Page 17 Installing the SmartSwitch 9000 Module SMB-1 PROM Flash SIMM Socket Boot PROM i960 Processor DIP Switch Local DRAM Socket Figure 2-2. User Accessible Components An eight-position DIP switch is located on the module card as shown in Figure 2-2. The function of the switches are listed in Table 2-1.
  • Page 18 Installing the SmartSwitch 9000 Module See the Cautions at the end of this table. Table 2-1. Function of DIP Switch Switch Function Description When toggled, this switch clears user-entered Clear passwords stored in NVRAM, and restores the default passwords. Once reset you can use the Password defaults or enter new passwords.
  • Page 19: Installing The Module Into The Smartswitch 9000 Chassis

    Installing the SmartSwitch 9000 Module Installing the Module into the SmartSwitch 9000 Chassis To install the SmartSwitch 9000 module, follow the steps below: The INB Terminator Modules must be installed on the rear of the chassis before NOTE powering up this module. Refer to the INB Terminator Modules Installation Guide for information and installation procedure.
  • Page 20 Installing the SmartSwitch 9000 Module Plastic Tab Jack for ESD Wrist Strap Metal Back-Panel Module Module Guides Warning: Ensure that the circuit card is between the card guides. Lock down the top and bottom plastic tabs at the same time, applying even pressure. Figure 2-3.
  • Page 21: The Reset Switch

    Installing the SmartSwitch 9000 Module The Reset Switch The Reset switch is located under the top plastic tab as shown in Figure 2-4. Use the reset switch to reset the module’s processor, shutdown (power down) the module, and/or restart the module. •...
  • Page 22 Installing the SmartSwitch 9000 Module...
  • Page 23: Chapter 3 Operation

    Chapter 3 Operation The 9F426-03 FDDI SmartSwitch Module is a four port switch module with three front panel FDDI interfaces and one INB-2 backplane interface. As shown in Figure 3-1, packets are received at the front panel FDDI ports and the INB-2 bus.
  • Page 24: Smb-1 Bus

    Operation SMB-1 Bus The SMB-1 is a 1Mbs management bus located within the SmartSwitch 9000. This bus is utilized by all diagnostic controllers in the system including connectivity modules, power supply modules and the environmental module. The SMB-1 transports inter-chassis information between system components, such as power and environmental information, as well as diagnostic messages.
  • Page 25: Inb Interface

    Operation INB Interface Each module that attaches to the INB has an INB Network Interface Block (NIB). The INB NIB converts canonical frames to fixed length data blocks for transmission onto the INB. For data blocks received from the INB, the INB NIB reassembles the data blocks received from the INB back into canonical frames for transmission to the SmartSwitch ASIC then from the SmartSwitch ASIC to the front panel ports.
  • Page 26: I960 Core

    Operation i960 Core The i960 core provides the SNMP protocol stacks to support industry standard MIBs. Additionally, Cabletron enterprise extension MIBs are supported for each media type. Advanced management services, such as the Distributed LAN Monitor, telnet and network address to MAC address mapping, are also provided by the i960 core.
  • Page 27: Lanview Leds

    Chapter 4 LANVIEW LEDs The front panel LANVIEW LEDs indicate the status of the module and may be used as an aid in troubleshooting. Shown in Figure 4-1 is the LANVIEW LEDs of the 9F426-03 module. FDDI 9F426-03 System Status INB Receive INB Transmit FDDI Receive...
  • Page 28 LANVIEW LEDs The functions of the two System Status LEDs, System Management Bus (SMB) and the CPU, are listed in Table 4-1. Table 4-1. System Status (SMB and CPU) LEDs LED Color State Description Green Functional Fully operational. Yellow Testing Power-up Testing Yellow (Flashing) Crippled...
  • Page 29 LANVIEW LEDs The functions of the FDDI receive LEDs are listed in Table 4-4. Table 4-4. FDDI Receive LEDs LED Color State Yellow (Flashing) Activity No Activity The functions of the FDDI Transmit LEDs are listed in Table 4-5. Table 4-5. FDDI Transmit LEDs LED Color State Green (Flashing)
  • Page 30 LANVIEW LEDs The functions of the FDDI Status LEDs are listed in Table 4-6. Table 4-6. FDDI Status LEDs STATE Green Green Ports Enabled and PCM Active Green Green Green THRU A Green Green Green THRU B Green Green Yellow Yellow WRAP A Yellow...
  • Page 31: Chapter 5 Specifications

    Chapter 5 Specifications Technical Specifications Intel i960 RISC based microprocessor Memory 4 Meg. Flash Memory (expandable to 32 Meg.) 16 Meg. DRAM Standards ANSI FDDI X3T9.5 MMF-PMD SMF-PMD Network Interface Cabletron FPIMs...
  • Page 32: Safety

    Specifications Safety It is the responsibility of the person who sells the system to which the module will be a part to ensure that the total system meets allowed limits of conducted and radiated emissions. CAUTION This equipment meets the safety requirements of: •...
  • Page 33 FPIM Specifications This SmartSwitch 9000 module uses Fiber Port Interface Modules (FPIM) to provide front panel cable connections. The FPIMs are user-installable. See section titled on page 2-1. Installing an FPIM FPIM-00 and FPIM-01 The FPIM-00 and FPIM-01 provide a multimode fiber connection. The FPIM-00 uses a MIC-style connector and the FPIM-01 uses an SC-type connector.
  • Page 34 FPIM Specifications Transmitter power parameters are listed in Table A-2. Table A-2. Transmitter Power Parameters Worst Case Typical Parameter Typical Value Worst Case Budget Budget 50/125 m fiber -13.0 dBm -15.0 dBm 13.0 dB 17.5 dB 62.5/125 m fiber -10.0 dBm -12.0 dBm 16.0 dB 20.5 dB...
  • Page 35 FPIM-05 and FPIM-07 FPIM-05 and FPIM-07 The FPIM-05 and FPIM-07 provide a Single-mode fiber connection. The FPIM-05 uses a MIC-style connector and the FPIM-07 uses an SC-type connector. The specifications for both devices are listed in Table A-4. Table A-4. FPIM-05 and FPIM-07 Specifications Parameter Typical Minimum...
  • Page 36 FPIM Specifications...

This manual is also suitable for:

Smartswitch 9000 9f426-03

Table of Contents