Linksys SPA2102-AU Provisioning Manual page 48

Provisioning guide
Table of Contents

Advertisement

Data Types
Example 3—SIT tone:
ProvisioningRuleSyntax—Scripting syntax used to define configuration resync and firmware
upgrade rules.
DialPlanScript—Scripting syntax used to specify Line 1 and Line 2 dial plans.
Notes:
<Par Name> represents a configuration parameter name. In a profile, the corresponding tag is
formed by replacing the space with an underscore "_", such as Par_Name.
An empty default value field implies an empty string < "" >.
The SPA continues to use the last configured values for tags that are not present in a given profile.
Templates are compared in the order given. The first, not the closest, match is selected. The
parameter name must match exactly.
If more than one definition for a parameter is given in a configuration file, the last such definition
in the file is the one that takes effect in the SPA.
A parameter specification with an empty parameter value forces the parameter back to its default
value. To specify an empty string instead, use the empty string "" as the parameter value.
Linksys SPA Provisioning Guide
2-22
Cadence Section 2: Section Length = 10s
Number of Segments = 1
Segment 1: On=forever, with Frequencies 1 and 2
Total Tone Length = 12s
985@-16,1428@-16,1777@-16;20(.380/0/1,.380/0/2,.380/0/3,0/4/0)
Number of Frequencies = 3
Frequency 1 = 985 Hz at –16 dBm
Frequency 2 = 1428 Hz at –16 dBm
Frequency 3 = 1777 Hz at –16 dBm
Number of Cadence Sections = 1
Cadence Section 1: Section Length = 20s
Number of Segments = 4
Segment 1: On=0.38s, Off=0s, with Frequency 1
Segment 2: On=0.38s, Off=0s, with Frequency 2
Segment 3: On=0.38s, Off=0s, with Frequency 3
Segment 4: On=0s, Off=4s, with no frequency components
Total Tone Length = 20s
Chapter 2
Creating Provisioning Scripts
Version 3.0

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents