The serial port connector requires a null-modem F/F DB9 cable. The pins on the switch RS-232 connector
(Figure
6) are identified in
port, see
"Connect the management station or workstation to the
Table 2
Serial port pin identification
Pin Number
1
2
3
4
5
6
7
8
9
Power supply and fans
The switch has a single power supply that converts 100–240 VAC to DC voltages for the various switch
circuits. Four internal fans provide cooling. The switch monitors internal air temperature, and therefore does
not monitor or report fan operational status. Air flow is front-to-back. To energize the switch, plug the
power cord into the switch AC receptacle (located on the back of the switch) and into a 100–240 VAC
power source.
Switch management
The switch supports the following management tools and protocols:
• QuickTools web
• Simple SAN Connection
• Command line
• Enterprise Fabric Management
• Simple Network Management
• Storage Management Initiative–Specification
• File transfer
Table
2. For information about connecting the workstation through the serial
Description
Carrier Detect
Receive Data
Transmit Data (TxD)
Data Terminal Ready (DTR)
Signal Ground (GND)
Data Set Ready (DSR)
Request to Send (RTS)
Clear to Send (CTS)
Ring Indicator (RI)
applet, page 14
Manager, page 14
interface, page 14
Suite, page 14
Protocol, page 14
protocols, page 15
HP StorageWorks 8/20q Fibre Channel Switch Installation and Reference Guide
switch" (page 38).
Referred to as
DCD
RxD
TxD
DTR
GND
DSR
RTS
CTS
RI
(SMI-S), page 15