Table 6-2
Class: HP_NumericSensor
Property name
SensorType
CurrentState
PossibleStates
CIM_NumericSensor
CurrentReading
BaseUnits
RateUnits
UnitModifier
SupportedThresholds
SettableThresholds
UpperThresholdNonCritical
UpperThresholdCritical
UpperThresholdFatal
HP_NumericSensor
NumericSensorType
Property implementation
2 (Temperature)
Normal—if OperationalStatus[0] is 2 (OK)
Critical—if OperationalStatus[0] is 6 (Error)
Array can contain any of the following values:
PossibleStates[9] = Normal
PossibleStates[3] = Critical
Current reading of temperature sensor
2 (Degrees C)
0 (None)
0
SupportedThresholds[0] = 1
(UpperThresholdNotCritical) if the system will set
fans to full speed if the threshold is crossed
SupportedThresholds[0] = 3
(UpperThresholdCritical) set if the system will
gracefully attempt to shutdown the system if the
threshold is crossed
SupportedThresholds[0] = 5 (UpperThresholdFatal)
if the system will immediately power down the
system if the threshold is crossed
<empty>
Contains the threshold temperature that
CurrentReading must exceed to be in a non-critical
state. This is only set if the system will set fans to full
speed if the threshold is crossed.
Contains the threshold temperature that
CurrentReading must exceed to be in a critical state.
This is only set if the system will gracefully attempt to
shutdown the system if the threshold is crossed.
Contains the threshold temperature that
CurrentReading must exceed to be fatal. This is only set
if the system will immediately power down the system if
the threshold is crossed.
Enumeration describing the type of temperature sensor.
Refer to MOF.