Table 13-90
HPSA_DeviceIndication: Physical Drive status changed to PREDICTIVE FAILURE
Property name
Summary
EventCategory
ProbableCause
NetworkAddresses
OSType
OSVersion
ProviderVersion
SystemFirmwareVersion
SystemSerialNumber
SystemProductID
SystemModel
SystemGUID
VariableNames
VariableTypes
VariableValues
ImpactedDomain
BladeBay *
BladeName *
EnclosureName *
RackName *
RackUID *
SystemVirtualSerialNumber
Property implementation
Physical Drive status is now PREDICTIVE FAILURE
6 (Primary Storage)
86 (Disk Failure)
A list of all the IP addresses of the computer system
generating the indication
•
For Windows 2003 64-bit: 70
•
For Windows 2008 64-bit: 77
Operating system version of the computer system
generating the indication in the format,
<major>.<minor>.<build>
2.2.0.0
Firmware version of the computer system generating
the indication
Serial number of the computer system generating the
indication
Product ID of the computer system generating the
indication
Model name of the computer system generating the
indication
Platform GUID of the computer system generating the
indication
•
VariableNames[0]: FailureDescription
•
VariableNames[1]: DriveInterface
•
VariableTypes[0]: 1 (String)
•
VariableTypes[1]: 4 (uint16)
•
VariableValues[0]: Short Description of failure
•
VariableValues[1]: HPSA_DiskDrive.DriveInterface
•
3 (Enclosure) for c-Class blade systems
•
4 (System) for all other systems
When ImpactedDomain is 3 (Enclosure), the properties
indicated with (*) are populated.
HP_BladeCSLocation.LocationInformation[0]
HP_ComputerSystem.Name
HP_BladeEnclosureCS.Name
Rack name if one exists
Rack Unique Identifier if one exists
Conditional property containing the virtual system
serial number string when running in a Virtual Connect
environment
12BSmart Array 204