Table 13-108
HPSA_DeviceIndication: Enclosure Temperature sensor status changed to OK
Property name
HWLogicalLocation
HWSerialNumber
HP_DeviceIndication
DeviceModel
Table 13-109
HPSA_DeviceIndication: Enclosure Temperature sensor status changed to Warning
Property name
CIM_Indication
IndicationIdentifier
PerceivedSeverity
IndicationTime
CIM_AlertIndication
Description
AlertingMangedElement
AlertingElementFormat
AlertType
EventID
ProviderName
RecommendedActions
SystemName
SystemCreationClassName
HP_AlertIndication
Summary
EventCategory
ProbableCause
NetworkAddresses
OSType
Property implementation
Enclosure Location string
For example, Port 1I Box 1
Enclosure Serial Number
Enclosure Model string
Property implementation
GUID string generated at indication
3 (Warning)
Time of indication
Temperature sensor Status changed to Warning
Condition. This indicates the enclosure temperature is
above normal, otherwise enclosure is still operating
normally.
WBEM path of the HPSA_StorageEnclosureProcessor
2 (CIMObjectPath)
5 (Device Alert)
1562
SmartArray
Verify fan and power supply operation for enclosure.
Verify ambient room temperature is within guidelines.
Name of the computer system generating the indication
CreationClassName of the computer system generating
the indication
Temperature sensor Status changed to Warning
Condition.
24 (Primary Storage Cooling)
51
A list of all the IP addresses of the computer system
generating the indication
•
For Windows 2003 64-bit: 70
•
For Windows 2008 64-bit: 77
12BSmart Array 240